Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2011 |
Principal Product | Plastic Toys |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 483 |
Plant Area (Sq.Ft.) | 382,816 |
Annual Production | 23,786,206 Pounds |
Production Hrs. Annual | 8,400 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $682,057 | 9,171,090 | kWh | $0.07 |
Electricity Demand | $43,536 | 16,008 | kW-months/year | $2.72 |
Natural Gas | $809,208 | 116,895 | MMBtu | $6.92 |
TOTAL ENERGY COSTS | $1,534,801 | |||
RECOMMENDED SAVINGS* | $267,339 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $57,346 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,006 Cost: - |
$4,795 | 62,299 | $255 | 84 | - | - | $(-44) | - |
$4,795 62,299 kWh |
$255 84 kW-months/year |
- - MMBtu |
$(-44) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $4,560 Cost: $5,325 |
$4,530 | 58,867 | $241 | 84 | - | - | $(-211) | - |
$4,530 58,867 kWh |
$241 84 kW-months/year |
- - MMBtu |
$(-211) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,753 Cost: $2,522 |
$3,177 | 41,283 | $28 | 10 | - | - | $548 | - |
$3,177 41,283 kWh |
$28 10 kW-months/year |
- - MMBtu |
$548 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $750 Cost: $2,910 |
$698 | 9,072 | $37 | 12 | - | - | $15 | - |
$698 9,072 kWh |
$37 12 kW-months/year |
- - MMBtu |
$15 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,725 Cost: $3,654 |
$2,588 | 33,615 | $137 | 48 | - | - | - | - |
$2,588 33,615 kWh |
$137 48 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $8,349 Cost: $16,000 |
$7,928 | 103,018 | $421 | 144 | - | - | - | - |
$7,928 103,018 kWh |
$421 144 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $29,274 Cost: $20,000 |
$27,798 | 361,200 | $1,476 | 516 | - | - | - | - |
$27,798 361,200 kWh |
$1,476 516 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $789 Cost: - |
$789 | 10,248 | - | - | - | - | - | - |
$789 10,248 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $3,663 Cost: $15,000 |
$3,478 | 45,192 | $185 | 60 | - | - | - | - |
$3,478 45,192 kWh |
$185 60 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,657 Cost: $500 |
$3,710 | 48,206 | $197 | 72 | - | - | $(-1,250) | - |
$3,710 48,206 kWh |
$197 72 kW-months/year |
- - MMBtu |
$(-1,250) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $74,004 Cost: $162,000 |
- | - | - | - | $74,004 | 10,694 | - | - |
- - kWh |
- - kW-months/year |
$74,004 10,694 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $76,354 Cost: $14,000 |
- | - | - | - | $76,354 | 11,034 | - | - |
- - kWh |
- - kW-months/year |
$76,354 11,034 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $4,187 Cost: - |
$4,187 | 54,404 | - | - | - | - | - | - |
$4,187 54,404 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $39,018 Cost: $150,000 |
$(-2,844) | (-39,960) | $(-378) | (-132) | $42,240 | 6,104 | - | - |
$(-2,844) (-39,960) kWh |
$(-378) (-132) kW-months/year |
$42,240 6,104 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $2,325 Cost: $3,523 |
- | - | - | - | $2,325 | 336 | - | - |
- - kWh |
- - kW-months/year |
$2,325 336 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
16: 2.7212 INSTALL OR UPGRADE INSULATION ON HVAC DISTRIBUTION SYSTEMS |
Savings: $9,925 Cost: $10,558 |
$9,925 | 128,966 | - | - | - | - | - | - |
$9,925 128,966 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $267,339 Cost: $405,992 |
$70,759 | 916,410 | $2,599 | 898 | $194,923 | 28,168 | $(-942) | - | $70,759 916,410 kWh |
$2,599 898 kW-months/year |
$194,923 28,168 MMBtu |
$(-942) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $57,346 Cost: $156,676 |
$15,613 | 199,847 | $239 | 82 | $42,240 | 6,104 | $(-746) | - | $15,613 199,847 kWh |
$239 82 kW-months/year |
$42,240 6,104 MMBtu |
$(-746) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |