Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2013
Principal Product Contract manufacturer primarily circuits and cables
NAICS 334412 - Bare Printed Circuit Board Manufacturing
SIC 3672 - Printed Circuit Boards
Sales $5,000,000-$10,000,000
# of Employees 85
Plant Area (Sq.Ft.) 42,000
Annual Production 280,000 Pieces
Production Hrs. Annual 2,250
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $60,120 778,195 kWh $0.08
Electricity Demand $16,388 3,348 kW-months/year $4.89
Natural Gas $6,716 711 MMBtu $9.45
TOTAL ENERGY COSTS $86,541
RECOMMENDED SAVINGS* $19,655 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $4,772
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Personnel Changes Administrative Changes Electricity Usage Electricity Demand Personnel Changes Administrative Changes
$ kWh $ kW-months/year $ $ $ $
01: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,161
Cost:
$2,100
$1,966 27,648 - - $195 - - - $1,966
27,648
kWh
-
-
kW-months/year
$195
-
$
-
-
$
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$104
Cost:
$90
$98 1,382 - - $6 - - - $98
1,382
kWh
-
-
kW-months/year
$6
-
$
-
-
$
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE Savings:
$1,986
Cost:
-
$1,986 25,750 - - - - - - $1,986
25,750
kWh
-
-
kW-months/year
-
-
$
-
-
$
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$521
Cost:
-
$408 5,289 $113 23 - - - - $408
5,289
kWh
$113
23
kW-months/year
-
-
$
-
-
$
05: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$14,883
Cost:
$105,000
$7,263 74,108 - - - - $7,620 - $7,263
74,108
kWh
-
-
kW-months/year
-
-
$
$7,620
-
$
TOTAL RECOMMENDED Savings:
$19,655
Cost:
$107,190
$11,721 134,177 $113 23 $201 - $7,620 - $11,721
134,177
kWh
$113
23
kW-months/year
$201
-
$
$7,620
-
$
TOTAL IMPLEMENTED Savings:
$4,772
Cost:
$2,190
$4,458 60,069 $113 23 $201 - - - $4,458
60,069
kWh
$113
23
kW-months/year
$201
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $
Electricity Usage Electricity Demand Personnel Changes Administrative Changes Electricity Usage Electricity Demand Personnel Changes Administrative Changes