Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2014 |
Principal Product | Roofing Products |
NAICS | 324122 - Asphalt Shingle and Coating Materials Manufacturing |
SIC | 2952 - Asphalt Felts And Coatings |
Sales | $100,000,000-$500,000,000 |
# of Employees | 35 |
Plant Area (Sq.Ft.) | 63,750 |
Annual Production | 1,285 Thousand Gallons |
Production Hrs. Annual | 4,320 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $107,671 | 2,136,248 | kWh | $0.05 |
Electricity Demand | $27,320 | 7,044 | kW-months/year | $3.88 |
Electricity Fees | $2,568 | - | $ | - |
Natural Gas | $192,655 | 32,350 | MMBtu | $5.96 |
TOTAL ENERGY COSTS | $330,214 | |||
RECOMMENDED SAVINGS* | $42,334 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,520 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $10,780 Cost: - |
- | - | - | - | $10,780 | 1,809 | - | - |
- - kWh |
- - kW-months/year |
$10,780 1,809 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $405 Cost: - |
- | - | - | - | $405 | 68 | - | - |
- - kWh |
- - kW-months/year |
$405 68 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $755 Cost: $1,000 |
$683 | 13,563 | $72 | 18 | - | - | - | - |
$683 13,563 kWh |
$72 18 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,897 Cost: $5,000 |
$2,434 | 48,341 | $463 | 358 | - | - | - | - |
$2,434 48,341 kWh |
$463 358 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $765 Cost: - |
$676 | 12,819 | $89 | 23 | - | - | - | - |
$676 12,819 kWh |
$89 23 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $3,409 Cost: $5,020 |
$2,556 | 50,769 | $628 | 120 | - | - | $225 | - |
$2,556 50,769 kWh |
$628 120 kW-months/year |
- - MMBtu |
$225 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $664 Cost: $600 |
$396 | 7,874 | $85 | 22 | - | - | $183 | - |
$396 7,874 kWh |
$85 22 kW-months/year |
- - MMBtu |
$183 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $142 Cost: $900 |
$142 | 2,830 | - | - | - | - | - | - |
$142 2,830 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7231 USE RADIANT HEATER FOR SPOT HEATING |
Savings: $22,517 Cost: $48,000 |
- | - | - | - | $22,517 | 3,778 | - | - |
- - kWh |
- - kW-months/year |
$22,517 3,778 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $42,334 Cost: $60,520 |
$6,887 | 136,196 | $1,337 | 540 | $33,702 | 5,655 | $408 | - | $6,887 136,196 kWh |
$1,337 540 kW-months/year |
$33,702 5,655 MMBtu |
$408 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,520 Cost: $1,000 |
$1,359 | 26,382 | $161 | 41 | - | - | - | - | $1,359 26,382 kWh |
$161 41 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes |