Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2015 |
Principal Product | Defense Combat Vehicles |
NAICS | 336992 - Military Armored Vehicle, Tank, and Tank Component Manufacturing |
SIC | 3795 - Tanks And Tank Components |
Sales | $100,000,000-$500,000,000 |
# of Employees | 450 |
Plant Area (Sq.Ft.) | 1,600,000 |
Annual Production | 150 Units |
Production Hrs. Annual | 2,125 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $3,263,002 | 46,527,600 | kWh | $0.07 |
Natural Gas | $662,576 | 146,030 | MMBtu | $4.54 |
Coal | $1,272,701 | 200,199 | MMBtu | $6.36 |
TOTAL ENERGY COSTS | $5,198,279 | |||
RECOMMENDED SAVINGS* | $1,756,262 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,087,445 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Coal | Electricity Usage | Natural Gas | Coal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.1331 BURN A LESS EXPENSIVE GRADE OF FUEL |
Savings: $424,424 Cost: - |
- | - | $(-255,234) | (-56,219) | $679,658 | 106,912 |
- - kWh |
$(-255,234) (-56,219) MMBtu |
$679,658 106,912 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $90,554 Cost: $10,250 |
- | - | - | - | $90,554 | 14,238 |
- - kWh |
- - MMBtu |
$90,554 14,238 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6232 INSTALL SET-BACK TIMERS |
Savings: $225,530 Cost: $1,200 |
$43,855 | 1,016,580 | $117,604 | 25,904 | $64,071 | 10,074 |
$43,855 1,016,580 kWh |
$117,604 25,904 MMBtu |
$64,071 10,074 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1241 REDUCE EXCESSIVE BOILER BLOWDOWN |
Savings: $61,951 Cost: $15,000 |
- | - | $40,352 | 8,888 | $21,599 | 3,396 |
- - kWh |
$40,352 8,888 MMBtu |
$21,599 3,396 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $4,522 Cost: $12,800 |
- | - | $4,522 | 996 | - | - |
- - kWh |
$4,522 996 MMBtu |
- - MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $658,499 Cost: $100,000 |
$112,915 | 2,617,416 | $355,655 | 78,338 | $189,929 | 29,863 |
$112,915 2,617,416 kWh |
$355,655 78,338 MMBtu |
$189,929 29,863 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $290,782 Cost: - |
$58,808 | 1,363,184 | $150,165 | 33,076 | $81,809 | 12,863 |
$58,808 1,363,184 kWh |
$150,165 33,076 MMBtu |
$81,809 12,863 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,756,262 Cost: $139,250 |
$215,578 | 4,997,180 | $413,064 | 90,983 | $1,127,620 | 177,346 | $215,578 4,997,180 kWh |
$413,064 90,983 MMBtu |
$1,127,620 177,346 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,087,445 Cost: $112,800 |
$112,915 | 2,617,416 | $104,943 | 23,115 | $869,587 | 136,775 | $112,915 2,617,416 kWh |
$104,943 23,115 MMBtu |
$869,587 136,775 MMBtu |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Coal | Electricity Usage | Natural Gas | Coal |