Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2015 |
Principal Product | Ice Cream and Beverages |
NAICS | 311520 - Ice Cream and Frozen Dessert Manufacturing |
SIC | 2024 - Ice Cream And Frozen Desserts |
Sales | $100,000,000-$500,000,000 |
# of Employees | 185 |
Plant Area (Sq.Ft.) | 145,350 |
Annual Production | 10,800 Thousand Gallons |
Production Hrs. Annual | 8,400 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $830,458 | 15,277,101 | kWh | $0.05 |
Electricity Demand | $59,042 | 32,364 | kW-months/year | $1.82 |
Electricity Fees | $78,400 | - | $ | - |
Natural Gas | $232,989 | 45,057 | MMBtu | $5.17 |
TOTAL ENERGY COSTS | $3,040,488 | |||
RECOMMENDED SAVINGS* | $217,536 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $4,865 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $39,463 Cost: - |
- | - | - | - | $39,463 | 7,633 | - | - | - | - |
- - kWh |
- - kW-months/year |
$39,463 7,633 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $3,298 Cost: - |
- | - | - | - | $3,298 | 638 | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,298 638 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $1,403 Cost: - |
- | - | $1,403 | 671 | - | - | - | - | - | - |
- - kWh |
$1,403 671 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4224 UPGRADE CONTROLS ON COMPRESSORS |
Savings: $107,431 Cost: - |
$99,557 | 1,984,000 | $7,874 | 3,768 | - | - | - | - | - | - |
$99,557 1,984,000 kWh |
$7,874 3,768 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2621 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE |
Savings: $29,938 Cost: $3,000 |
$27,889 | 555,775 | $2,049 | 980 | - | - | - | - | - | - |
$27,889 555,775 kWh |
$2,049 980 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,415 Cost: - |
$1,300 | 25,911 | $115 | 55 | - | - | - | - | - | - |
$1,300 25,911 kWh |
$115 55 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $152 Cost: $530 |
$136 | 2,713 | $16 | 8 | - | - | - | - | - | - |
$136 2,713 kWh |
$16 8 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,596 Cost: $20,100 |
$4,341 | 86,500 | $255 | 122 | - | - | - | - | - | - |
$4,341 86,500 kWh |
$255 122 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $807 Cost: $3,133 |
$1,054 | 21,000 | $125 | 60 | $(-372) | (-72) | - | - | - | - |
$1,054 21,000 kWh |
$125 60 kW-months/year |
$(-372) (-72) MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,880 Cost: $15,000 |
$1,774 | 35,362 | $106 | 51 | - | - | - | - | - | - |
$1,774 35,362 kWh |
$106 51 kW-months/year |
- - MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 3.4151 MINIMIZE WATER USAGE |
Savings: $27,153 Cost: $9,300 |
$(-410) | (-8,169) | $(-23) | (-11) | - | - | $27,320 | 526 | $266 | - |
$(-410) (-8,169) kWh |
$(-23) (-11) kW-months/year |
- - MMBtu |
$27,320 526 Tgal |
$266 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $217,536 Cost: $51,063 |
$135,641 | 2,703,092 | $11,920 | 5,703 | $42,389 | 8,199 | $27,320 | 526 | $266 | - | $135,641 2,703,092 kWh |
$11,920 5,703 kW-months/year |
$42,389 8,199 MMBtu |
$27,320 526 Tgal |
$266 - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $4,865 Cost: $530 |
$1,436 | 28,624 | $131 | 63 | $3,298 | 638 | - | - | - | - | $1,436 28,624 kWh |
$131 63 kW-months/year |
$3,298 638 MMBtu |
- - Tgal |
- - Tgal |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | Tgal | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Water Consumption |