Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2017 |
Principal Product | Sunroofs |
NAICS | 336390 - Other Motor Vehicle Parts Manufacturing |
SIC | 3714 - Motor Vehicle Parts And Accessories |
Sales | $100,000,000-$500,000,000 |
# of Employees | 380 |
Plant Area (Sq.Ft.) | 128,755 |
Annual Production | 1,096,625 Units |
Production Hrs. Annual | 5,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $263,110 | 3,556,000 | kWh | $0.07 |
Electricity Demand | $42,159 | 8,448 | kW-months/year | $4.99 |
Electricity Fees | $2,462 | - | $ | - |
Natural Gas | $91,718 | 16,682 | MMBtu | $5.50 |
TOTAL ENERGY COSTS | $428,743 | |||
RECOMMENDED SAVINGS* | $45,835 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $7,371 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $8,133 Cost: $4,500 |
$8,133 | 109,694 | - | - | - | - | - | - |
$8,133 109,694 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $4,232 Cost: $400 |
- | - | - | - | $4,232 | 769 | - | - |
- - kWh |
- - kW-months/year |
$4,232 769 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $3,139 Cost: - |
$3,139 | 42,342 | - | - | - | - | - | - |
$3,139 42,342 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.1123 INSTALL AUTOMATIC STACK DAMPER |
Savings: $1,358 Cost: $548 |
- | - | - | - | $1,358 | 247 | - | - |
- - kWh |
- - kW-months/year |
$1,358 247 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $8,870 Cost: $37,000 |
$8,168 | 110,160 | $702 | 204 | - | - | - | - |
$8,168 110,160 kWh |
$702 204 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES |
Savings: $5,095 Cost: $4,624 |
$5,095 | 68,717 | - | - | - | - | - | - |
$5,095 68,717 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,311 Cost: - |
$4,193 | 56,549 | $278 | 81 | - | - | $(-2,160) | - |
$4,193 56,549 kWh |
$278 81 kW-months/year |
- - MMBtu |
$(-2,160) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $648 Cost: - |
$481 | 6,486 | $167 | 49 | - | - | - | - |
$481 6,486 kWh |
$167 49 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $1,428 Cost: $3,701 |
$1,168 | 15,748 | $260 | 76 | - | - | - | - |
$1,168 15,748 kWh |
$260 76 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $2,250 Cost: $3,655 |
$1,840 | 24,821 | $410 | 119 | - | - | - | - |
$1,840 24,821 kWh |
$410 119 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,727 Cost: $21,847 |
$4,982 | 67,200 | $555 | 161 | - | - | $190 | - |
$4,982 67,200 kWh |
$555 161 kW-months/year |
- - MMBtu |
$190 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,242 Cost: $7,925 |
$1,774 | 23,929 | $329 | 96 | - | - | $139 | - |
$1,774 23,929 kWh |
$329 96 kW-months/year |
- - MMBtu |
$139 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $402 Cost: $630 |
$362 | 4,885 | $40 | 12 | - | - | - | - |
$362 4,885 kWh |
$40 12 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $45,835 Cost: $84,830 |
$39,335 | 530,531 | $2,741 | 797 | $5,590 | 1,016 | $(-1,831) | - | $39,335 530,531 kWh |
$2,741 797 kW-months/year |
$5,590 1,016 MMBtu |
$(-1,831) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $7,371 Cost: $400 |
$3,139 | 42,342 | - | - | $4,232 | 769 | - | - | $3,139 42,342 kWh |
- - kW-months/year |
$4,232 769 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes |