Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2017 |
Principal Product | Acrylonitrile, Acetonitrile, Hydrogen Cyanide |
NAICS | 325110 - Petrochemical Manufacturing |
SIC | 2869 - Industrial Organic Chemicals, Nec |
Sales | $100,000,000-$500,000,000 |
# of Employees | 300 |
Plant Area (Sq.Ft.) | 2,500,000 |
Annual Production | 360,000,000 Pounds |
Production Hrs. Annual | 7,140 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $4,163,355 | 69,658,440 | kWh | $0.06 |
Natural Gas | $2,136,481 | 718,509 | MMBtu | $2.97 |
TOTAL ENERGY COSTS | $6,385,766 | |||
RECOMMENDED SAVINGS* | $1,270,996 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $383,642 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Administrative Changes | Electricity Usage | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE |
Savings: $217,648 Cost: $48,962 |
$186,784 | 3,125,058 | - | - | $30,864 | - |
$186,784 3,125,058 kWh |
- - MMBtu |
$30,864 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS |
Savings: $12,245 Cost: $25,000 |
$12,245 | 204,871 | - | - | - | - |
$12,245 204,871 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY |
Savings: $270,579 Cost: $100,000 |
- | - | $270,579 | 91,104 | - | - |
- - kWh |
$270,579 91,104 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $8,225 Cost: $4,000 |
$8,225 | 137,606 | - | - | - | - |
$8,225 137,606 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS |
Savings: $57,432 Cost: $35,000 |
$57,432 | 960,887 | - | - | - | - |
$57,432 960,887 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $14,748 Cost: $4,000 |
$14,748 | 246,753 | - | - | - | - |
$14,748 246,753 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $383,642 Cost: $613,600 |
$383,642 | 6,418,640 | - | - | - | - |
$383,642 6,418,640 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.3321 USE STEAM PRESSURE REDUCTION TO GENERATE POWER |
Savings: $229,882 Cost: $595,039 |
$275,310 | 4,588,488 | - | - | $(-45,428) | - |
$275,310 4,588,488 kWh |
- - MMBtu |
$(-45,428) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3321 USE STEAM PRESSURE REDUCTION TO GENERATE POWER |
Savings: $76,595 Cost: $198,657 |
$91,914 | 1,532,124 | - | - | $(-15,319) | - |
$91,914 1,532,124 kWh |
- - MMBtu |
$(-15,319) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,270,996 Cost: $1,624,258 |
$1,030,300 | 17,214,427 | $270,579 | 91,104 | $(-29,883) | - | $1,030,300 17,214,427 kWh |
$270,579 91,104 MMBtu |
$(-29,883) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $383,642 Cost: $613,600 |
$383,642 | 6,418,640 | - | - | - | - | $383,642 6,418,640 kWh |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Administrative Changes | Electricity Usage | Natural Gas | Administrative Changes |