Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2017
Principal Product Acrylonitrile, Acetonitrile, Hydrogen Cyanide
NAICS 325110 - Petrochemical Manufacturing
SIC 2869 - Industrial Organic Chemicals, Nec
Sales $100,000,000-$500,000,000
# of Employees 300
Plant Area (Sq.Ft.) 2,500,000
Annual Production 360,000,000 Pounds
Production Hrs. Annual 7,140
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $4,163,355 69,658,440 kWh $0.06
Natural Gas $2,136,481 718,509 MMBtu $2.97
TOTAL ENERGY COSTS $6,385,766
RECOMMENDED SAVINGS* $1,270,996 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $383,642
#|Description Savings
Cost
Status Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes
$ kWh $ MMBtu $ $
01: 2.2694 USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE Savings:
$217,648
Cost:
$48,962
$186,784 3,125,058 - - $30,864 - $186,784
3,125,058
kWh
-
-
MMBtu
$30,864
-
$
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$12,245
Cost:
$25,000
$12,245 204,871 - - - - $12,245
204,871
kWh
-
-
MMBtu
-
-
$
03: 2.1116 IMPROVE COMBUSTION CONTROL CAPABILITY Savings:
$270,579
Cost:
$100,000
- - $270,579 91,104 - - -
-
kWh
$270,579
91,104
MMBtu
-
-
$
04: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$8,225
Cost:
$4,000
$8,225 137,606 - - - - $8,225
137,606
kWh
-
-
MMBtu
-
-
$
05: 2.7291 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS Savings:
$57,432
Cost:
$35,000
$57,432 960,887 - - - - $57,432
960,887
kWh
-
-
MMBtu
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$14,748
Cost:
$4,000
$14,748 246,753 - - - - $14,748
246,753
kWh
-
-
MMBtu
-
-
$
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$383,642
Cost:
$613,600
$383,642 6,418,640 - - - - $383,642
6,418,640
kWh
-
-
MMBtu
-
-
$
08: 2.3321 USE STEAM PRESSURE REDUCTION TO GENERATE POWER Savings:
$229,882
Cost:
$595,039
$275,310 4,588,488 - - $(-45,428) - $275,310
4,588,488
kWh
-
-
MMBtu
$(-45,428)
-
$
09: 2.3321 USE STEAM PRESSURE REDUCTION TO GENERATE POWER Savings:
$76,595
Cost:
$198,657
$91,914 1,532,124 - - $(-15,319) - $91,914
1,532,124
kWh
-
-
MMBtu
$(-15,319)
-
$
TOTAL RECOMMENDED Savings:
$1,270,996
Cost:
$1,624,258
$1,030,300 17,214,427 $270,579 91,104 $(-29,883) - $1,030,300
17,214,427
kWh
$270,579
91,104
MMBtu
$(-29,883)
-
$
TOTAL IMPLEMENTED Savings:
$383,642
Cost:
$613,600
$383,642 6,418,640 - - - - $383,642
6,418,640
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas Administrative Changes Electricity Usage Natural Gas Administrative Changes