Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2018 |
Principal Product | Pumps |
NAICS | 333911 - Pump and Pumping Equipment Manufacturing |
SIC | 3561 - Pumps And Pumping Equipment |
Sales | $50,000,000-$100,000,000 |
# of Employees | 175 |
Plant Area (Sq.Ft.) | 191,000 |
Annual Production | 72,258 Units |
Production Hrs. Annual | 6,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $134,287 | 2,827,092 | kWh | $0.05 |
Electricity Demand | $124,441 | 8,214 | kW-months/year | $15.15 |
Electricity Fees | $780 | - | $ | - |
Natural Gas | $14,172 | 1,485 | MMBtu | $9.54 |
TOTAL ENERGY COSTS | $282,688 | |||
RECOMMENDED SAVINGS* | $51,006 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $49,748 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $2,113 Cost: - |
$2,113 | 44,474 | - | - | - | - | - | - | - | - |
$2,113 44,474 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,260 Cost: $1,000 |
$1,989 | 43,641 | $1,271 | 84 | - | - | - | - | - | - |
$1,989 43,641 kWh |
$1,271 84 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $957 Cost: $2,500 |
$666 | 14,016 | $291 | 19 | - | - | - | - | - | - |
$666 14,016 kWh |
$291 19 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $938 Cost: - |
$574 | 12,840 | $364 | 24 | - | - | - | - | - | - |
$574 12,840 kWh |
$364 24 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $320 Cost: $1,500 |
$223 | 4,688 | $97 | 6 | - | - | - | - | - | - |
$223 4,688 kWh |
$97 6 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,998 Cost: $55,816 |
$2,589 | 54,510 | $3,964 | 262 | - | - | $6,445 | - | - | - |
$2,589 54,510 kWh |
$3,964 262 kW-months/year |
- - lb |
$6,445 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $30,420 Cost: $25,000 |
- | - | - | - | $36,000 | 4,000 | $(-7,380) | - | $1,800 | - |
- - kWh |
- - kW-months/year |
$36,000 4,000 lb |
$(-7,380) - $ |
$1,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $51,006 Cost: $85,816 |
$8,154 | 174,169 | $5,987 | 395 | $36,000 | 4,000 | $(-935) | - | $1,800 | - | $8,154 174,169 kWh |
$5,987 395 kW-months/year |
$36,000 4,000 lb |
$(-935) - $ |
$1,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $49,748 Cost: $84,316 |
$7,357 | 156,641 | $5,526 | 365 | $36,000 | 4,000 | $(-935) | - | $1,800 | - | $7,357 156,641 kWh |
$5,526 365 kW-months/year |
$36,000 4,000 lb |
$(-935) - $ |
$1,800 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Personnel Changes | By-product Production |