Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2018 |
Principal Product | Tubing |
NAICS | 331210 - Iron and Steel Pipe and Tube Manufacturing from Purchased Steel |
SIC | 3317 - Steel Pipe And Tubes |
Sales | $100,000,000-$500,000,000 |
# of Employees | 169 |
Plant Area (Sq.Ft.) | 300,000 |
Annual Production | 72,610 Tons |
Production Hrs. Annual | 6,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $526,834 | 6,668,779 | kWh | $0.08 |
Electricity Demand | $3,142 | 26,517 | kW-months/year | $0.12 |
Electricity Fees | $74,845 | - | $ | - |
Natural Gas | $18,695 | 2,807 | MMBtu | $6.66 |
TOTAL ENERGY COSTS | $631,800 | |||
RECOMMENDED SAVINGS* | $133,216 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,680 Cost: $4,200 |
$5,858 | 74,153 | - | - | - | - | - | - | - | - | $2,822 | - |
$5,858 74,153 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - $ |
$2,822 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $574 Cost: $1,000 |
$8,486 | 107,424 | - | - | - | - | - | - | $(-12,000) | - | $4,088 | - |
$8,486 107,424 kWh |
- - kW-months/year |
- - $ |
- - Tgal |
$(-12,000) - $ |
$4,088 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $72,351 Cost: $48,000 |
- | - | - | - | $72,351 | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$72,351 - $ |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $7,458 Cost: $400 |
- | - | - | - | - | - | $7,458 | 629 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$7,458 629 Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,774 Cost: $10,470 |
$2,766 | 35,008 | $8 | 70 | - | - | - | - | - | - | - | - |
$2,766 35,008 kWh |
$8 70 kW-months/year |
- - $ |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $41,379 Cost: $200,263 |
$41,254 | 522,200 | $125 | 1,044 | - | - | - | - | - | - | - | - |
$41,254 522,200 kWh |
$125 1,044 kW-months/year |
- - $ |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $133,216 Cost: $264,333 |
$58,364 | 738,785 | $133 | 1,114 | $72,351 | - | $7,458 | 629 | $(-12,000) | - | $6,910 | - | $58,364 738,785 kWh |
$133 1,114 kW-months/year |
$72,351 - $ |
$7,458 629 Tgal |
$(-12,000) - $ |
$6,910 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - Tgal |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | Tgal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Electricity Fees | Water Disposal | Personnel Changes | One-time Revenue or Avoided Cost |