Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2020 |
Principal Product | Rubber Product |
NAICS | 326299 - All Other Rubber Product Manufacturing |
SIC | 3061 - Mechanical Rubber Goods |
Sales | $10,000,000-$50,000,000 |
# of Employees | 192 |
Plant Area (Sq.Ft.) | 55,000 |
Annual Production | 7,000,000 Pounds |
Production Hrs. Annual | 7,344 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $266,949 | 5,266,298 | kWh | $0.05 |
Electricity Demand | $25,058 | 11,112 | kW-months/year | $2.26 |
Electricity Fees | $147,294 | - | $ | - |
TOTAL ENERGY COSTS | $506,258 | |||
RECOMMENDED SAVINGS* | $120,095 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $26,744 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,208 Cost: - |
$1,121 | 22,112 | $87 | 38 | - | - | - | - | - | - |
$1,121 22,112 kWh |
$87 38 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) |
Savings: $75,593 Cost: $7,810 |
- | - | - | - | $14,591 | 4,198 | $61,002 | 4,198 | - | - |
- - kWh |
- - kW-months/year |
$14,591 4,198 Tgal |
$61,002 4,198 Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $9,464 Cost: $1,012 |
$8,823 | 174,025 | $641 | 284 | - | - | - | - | - | - |
$8,823 174,025 kWh |
$641 284 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $768 Cost: $203 |
$579 | 11,424 | $189 | 84 | - | - | - | - | - | - |
$579 11,424 kWh |
$189 84 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $9,951 Cost: $5,000 |
$9,277 | 183,012 | $674 | 299 | - | - | - | - | - | - |
$9,277 183,012 kWh |
$674 299 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,346 Cost: $1,000 |
$4,850 | 95,685 | $296 | 131 | - | - | - | - | $(-1,800) | - |
$4,850 95,685 kWh |
$296 131 kW-months/year |
- - Tgal |
- - Tgal |
$(-1,800) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4226 USE / PURCHASE OPTIMUM SIZED COMPRESSOR |
Savings: $792 Cost: $600 |
$785 | 15,489 | $7 | 3 | - | - | - | - | - | - |
$785 15,489 kWh |
$7 3 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $12,239 Cost: $14,500 |
$10,521 | 207,556 | $765 | 340 | - | - | - | - | $953 | - |
$10,521 207,556 kWh |
$765 340 kW-months/year |
- - Tgal |
- - Tgal |
$953 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $1,053 Cost: $1,800 |
$1,053 | 20,768 | - | - | - | - | - | - | - | - |
$1,053 20,768 kWh |
- - kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.4114 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER |
Savings: $5,681 Cost: $21,000 |
$5,485 | 108,199 | $196 | 87 | - | - | - | - | - | - |
$5,485 108,199 kWh |
$196 87 kW-months/year |
- - Tgal |
- - Tgal |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $120,095 Cost: $52,925 |
$42,494 | 838,270 | $2,855 | 1,267 | $14,591 | 4,198 | $61,002 | 4,198 | $(-847) | - | $42,494 838,270 kWh |
$2,855 1,267 kW-months/year |
$14,591 4,198 Tgal |
$61,002 4,198 Tgal |
$(-847) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $26,744 Cost: $20,500 |
$25,769 | 508,365 | $1,822 | 808 | - | - | - | - | $(-847) | - | $25,769 508,365 kWh |
$1,822 808 kW-months/year |
- - Tgal |
- - Tgal |
$(-847) - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | Tgal | $ | Tgal | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes | Electricity Usage | Electricity Demand | Water Usage | Water Disposal | Personnel Changes |