IAC logo
IAC Assessment: UD1019
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: UD1019
IAC Center University of Dayton
Assessment Year 2020
Principal Product Inkjet Printing Systems and Consumables
NAICS 333244 - Printing Machinery and Equipment Manufacturing
SIC 3555 - Printing Trades Machinery
Sales $100,000,000-$500,000,000
# of Employees 299
Plant Area (Sq.Ft.) 315,000
Annual Production 533,117 Units
Production Hrs. Annual 6,240
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $801,378 17,651,504 kWh $0.05
Electricity Demand $118,707 32,460 kW-months/year $3.66
Electricity Fees $315,878 - $ -
Natural Gas $191,113 46,463 MMBtu $4.11
TOTAL ENERGY COSTS $1,521,182
RECOMMENDED SAVINGS* $86,955 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $15,303
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Water Usage Personnel Changes Electricity Usage Electricity Demand Natural Gas Water Usage Personnel Changes
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
01: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$2,684
Cost:
-
- - - - $2,684 653 - - - - -
-
kWh
-
-
kW-months/year
$2,684
653
MMBtu
-
-
Tgal
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,924
Cost:
$1,000
$4,380 108,405 $544 149 - - - - - - $4,380
108,405
kWh
$544
149
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$4,086
Cost:
-
$3,635 89,974 $451 124 - - - - - - $3,635
89,974
kWh
$451
124
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
04: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) Savings:
$9,326
Cost:
$1,400
- - - - - - $9,326 1,481 - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$9,326
1,481
Tgal
-
-
$
05: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$28,713
Cost:
$11,014
$14,027 347,199 - - $14,686 3,574 - - - - $14,027
347,199
kWh
-
-
kW-months/year
$14,686
3,574
MMBtu
-
-
Tgal
-
-
$
06: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT Savings:
$21,134
Cost:
$7,500
$21,134 522,618 - - - - - - - - $21,134
522,618
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
Tgal
-
-
$
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$12,619
Cost:
$82,620
$7,991 197,803 $3,035 830 - - - - $1,593 - $7,991
197,803
kWh
$3,035
830
kW-months/year
-
-
MMBtu
-
-
Tgal
$1,593
-
$
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,469
Cost:
$10,920
$2,952 73,058 $732 200 - - - - $(-215) - $2,952
73,058
kWh
$732
200
kW-months/year
-
-
MMBtu
-
-
Tgal
$(-215)
-
$
TOTAL RECOMMENDED Savings:
$86,955
Cost:
$114,454
$54,119 1,339,057 $4,762 1,303 $17,370 4,227 $9,326 1,481 $1,378 - $54,119
1,339,057
kWh
$4,762
1,303
kW-months/year
$17,370
4,227
MMBtu
$9,326
1,481
Tgal
$1,378
-
$
TOTAL IMPLEMENTED Savings:
$15,303
Cost:
$82,620
$7,991 197,803 $3,035 830 $2,684 653 - - $1,593 - $7,991
197,803
kWh
$3,035
830
kW-months/year
$2,684
653
MMBtu
-
-
Tgal
$1,593
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ Tgal $ $
Electricity Usage Electricity Demand Natural Gas Water Usage Personnel Changes Electricity Usage Electricity Demand Natural Gas Water Usage Personnel Changes