Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Dayton |
---|---|
Assessment Year | 2020 |
Principal Product | Coated and Laminated Paper |
NAICS | 322220 - Paper Bag and Coated and Treated Paper Manufacturing |
SIC | 2672 - Paper Coated And Laminated, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 100 |
Plant Area (Sq.Ft.) | 55,150 |
Annual Production | 100,000,000 Units |
Production Hrs. Annual | 6,000 |
Location (State) | OH |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $215,696 | 4,419,995 | kWh | $0.05 |
Electricity Demand | $90,899 | 9,228 | kW-months/year | $9.85 |
Electricity Fees | $21,536 | - | $ | - |
Natural Gas | $260,860 | 52,462 | MMBtu | $4.97 |
TOTAL ENERGY COSTS | $592,528 | |||
RECOMMENDED SAVINGS* | $616,864 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $16,051 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $2,747 Cost: - |
- | - | - | - | $2,747 | 553 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,747 553 MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $16,051 Cost: $340 |
$12,717 | 260,605 | $5,134 | 521 | - | - | $(-1,800) | - | - | - | - | - | - | - |
$12,717 260,605 kWh |
$5,134 521 kW-months/year |
- - MMBtu |
$(-1,800) - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,411 Cost: $4,000 |
$1,005 | 20,599 | $406 | 41 | - | - | - | - | - | - | - | - | - | - |
$1,005 20,599 kWh |
$406 41 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $83,809 Cost: $25,133 |
- | - | - | - | $83,809 | 16,863 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$83,809 16,863 MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1241 REDUCE EXCESSIVE BOILER BLOWDOWN |
Savings: $6,710 Cost: $5,224 |
- | - | - | - | $6,710 | 1,350 | - | - | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$6,710 1,350 MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.8112 COMBINE UTILITY METERS |
Savings: $8,278 Cost: - |
- | - | - | - | - | - | - | - | $8,278 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$8,278 - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $3,612 Cost: $7,325 |
- | - | $3,612 | 367 | - | - | - | - | - | - | - | - | - | - |
- - kWh |
$3,612 367 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $27,963 Cost: $26,366 |
$17,627 | 361,203 | $7,116 | 722 | - | - | - | - | - | - | $3,220 | - | - | - |
$17,627 361,203 kWh |
$7,116 722 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$3,220 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $11,875 Cost: $4,845 |
$6,704 | 137,375 | $2,706 | 275 | - | - | - | - | - | - | $2,465 | - | - | - |
$6,704 137,375 kWh |
$2,706 275 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
$2,465 - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.445 INSTALL EQUIPMENT TO MOVE PRODUCT |
Savings: $454,408 Cost: $375,000 |
$4,408 | 90,333 | - | - | - | - | - | - | - | - | - | - | $450,000 | - |
$4,408 90,333 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
$450,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $616,864 Cost: $448,233 |
$42,461 | 870,115 | $18,974 | 1,926 | $93,266 | 18,766 | $(-1,800) | - | $8,278 | - | $5,685 | - | $450,000 | - | $42,461 870,115 kWh |
$18,974 1,926 kW-months/year |
$93,266 18,766 MMBtu |
$(-1,800) - $ |
$8,278 - $ |
$5,685 - $ |
$450,000 - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $16,051 Cost: $340 |
$12,717 | 260,605 | $5,134 | 521 | - | - | $(-1,800) | - | - | - | - | - | - | - | $12,717 260,605 kWh |
$5,134 521 kW-months/year |
- - MMBtu |
$(-1,800) - $ |
- - $ |
- - $ |
- - % |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Increase in Production | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Increase in Production |