IAC logo
IAC Assessment: UD1122
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UD1122
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Dayton
Assessment Year 2025
Principal Product Education
NAICS 611110 - Elementary and Secondary Schools
SIC 8211 - Elementary And Secondary Schools
Sales <$500,000
# of Employees 120
Plant Area (Sq.Ft.) 99,875
Annual Production 1 Units
Production Hrs. Annual 2,000
Location (State) OH
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $131,656 1,086,979 kWh $0.12
LPG $59,116 4,325 MMBtu $13.67
TOTAL ENERGY COSTS $190,772
RECOMMENDED SAVINGS* $144,835 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage LPG Electricity Usage LPG
$ kWh $ MMBtu
01: 2.7234 USE HEAT PUMP FOR SPACE CONDITIONING Savings:
$46,945
Cost:
$400,000
$(-19,757) (-163,115) $66,702 4,880 $(-19,757)
(-163,115)
kWh
$66,702
4,880
MMBtu
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$534
Cost:
$4,000
$534 4,406 - - $534
4,406
kWh
-
-
MMBtu
03: 2.2441 PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT Savings:
$1,430
Cost:
$7,500
- - $1,430 105 -
-
kWh
$1,430
105
MMBtu
04: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD Savings:
$124
Cost:
$300
$124 1,024 - - $124
1,024
kWh
-
-
MMBtu
05: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$2,853
Cost:
$25,000
$(-1,196) (-9,871) $4,049 296 $(-1,196)
(-9,871)
kWh
$4,049
296
MMBtu
06: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$92,949
Cost:
$900,000
$92,949 767,401 - - $92,949
767,401
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$144,835
Cost:
$1,336,800
$72,654 599,845 $72,181 5,281 $72,654
599,845
kWh
$72,181
5,281
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage LPG Electricity Usage LPG