Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1996
Principal Product Fiberglass Boats
NAICS n/a
SIC 3732 - Boat Building And Repairing
Sales $10,000,000-$50,000,000
# of Employees 152
Plant Area (Sq.Ft.) 250,000
Annual Production 250 Pieces
Production Hrs. Annual 5,330
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $91,224 1,645,369 kWh $0.06
Electricity Demand $22,784 4,810 kW-months/year $4.74
TOTAL ENERGY COSTS $137,971
RECOMMENDED SAVINGS* $42,091 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,354
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Solid Waste (non-haz) Solid Waste (haz) Primary Raw Material By-product Production Electricity Usage Electricity Demand Solid Waste (non-haz) Solid Waste (haz) Primary Raw Material By-product Production
$ kWh $ kW-months/year $ lb $ lb $ $ $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$1,365
Cost:
-
$1,143 20,809 $222 47 - - - - - - - - $1,143
20,809
kWh
$222
47
kW-months/year
-
-
lb
-
-
lb
-
-
$
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,698
Cost:
$3,997
$2,197 39,859 $501 106 - - - - - - - - $2,197
39,859
kWh
$501
106
kW-months/year
-
-
lb
-
-
lb
-
-
$
-
-
$
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$4,777
Cost:
$4,300
$3,150 57,151 $1,627 343 - - - - - - - - $3,150
57,151
kWh
$1,627
343
kW-months/year
-
-
lb
-
-
lb
-
-
$
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,879
Cost:
$1,000
$3,879 56,272 - - - - - - - - - - $3,879
56,272
kWh
-
-
kW-months/year
-
-
lb
-
-
lb
-
-
$
-
-
$
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER Savings:
$16,182
Cost:
$7,020
- - - - $9,563 300,900 - - - - $6,619 - -
-
kWh
-
-
kW-months/year
$9,563
300,900
lb
-
-
lb
-
-
$
$6,619
-
$
06: 3.8132 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES Savings:
$13,190
Cost:
-
- - - - - - $4,800 1,980 $8,390 - - - -
-
kWh
-
-
kW-months/year
-
-
lb
$4,800
1,980
lb
$8,390
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$42,091
Cost:
$16,317
$10,369 174,091 $2,350 496 $9,563 300,900 $4,800 1,980 $8,390 - $6,619 - $10,369
174,091
kWh
$2,350
496
kW-months/year
$9,563
300,900
lb
$4,800
1,980
lb
$8,390
-
$
$6,619
-
$
TOTAL IMPLEMENTED Savings:
$11,354
Cost:
$9,297
$9,226 153,282 $2,128 449 - - - - - - - - $9,226
153,282
kWh
$2,128
449
kW-months/year
-
-
lb
-
-
lb
-
-
$
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ lb $ lb $ $ $ $
Electricity Usage Electricity Demand Solid Waste (non-haz) Solid Waste (haz) Primary Raw Material By-product Production Electricity Usage Electricity Demand Solid Waste (non-haz) Solid Waste (haz) Primary Raw Material By-product Production