IAC logo
IAC Assessment: UF0185
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0185
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1997
Principal Product PVC Pipe
NAICS n/a
SIC 3084 - Plastics Pipe
Sales $50,000,000-$100,000,000
# of Employees 120
Plant Area (Sq.Ft.) 80,000
Annual Production 90,000,000 Pounds
Production Hrs. Annual 8,760
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $596,680 15,604,045 kWh $0.04
Electricity Demand $209,193 26,219 kW-months/year $7.98
TOTAL ENERGY COSTS $805,873
RECOMMENDED SAVINGS* $504,801 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $494,931
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$2,893
Cost:
$4,059
$2,163 56,858 $730 93 - - $2,163
56,858
kWh
$730
93
kW-months/year
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$7,979
Cost:
$1,725
$7,979 156,506 - - - - $7,979
156,506
kWh
-
-
kW-months/year
-
-
$
03: 2.5117 CONVERT TO INDIRECT TEMPERATURE CONTROL SYSTEM Savings:
$20,417
Cost:
$19,200
$20,417 390,094 - - - - $20,417
390,094
kWh
-
-
kW-months/year
-
-
$
04: 2.2622 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL Savings:
$11,382
Cost:
$32,000
$8,556 225,088 $2,826 360 - - $8,556
225,088
kWh
$2,826
360
kW-months/year
-
-
$
05: 3.5212 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS Savings:
$9,870
Cost:
$31,000
- - - - $9,870 - -
-
kWh
-
-
kW-months/year
$9,870
-
$
06: 3.4145 USE MAGNETIC TECHNOLOGY TO TREAT WATER Savings:
$11,000
Cost:
$43,500
- - - - $11,000 - -
-
kWh
-
-
kW-months/year
$11,000
-
$
07: 4.1130 INSTALL REFRIGERATION SYSTEM TO COOL PRODUCT Savings:
$420,104
Cost:
$47,500
- - - - $420,104 - -
-
kWh
-
-
kW-months/year
$420,104
-
$
08: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$21,156
Cost:
-
- - - - $21,156 - -
-
kWh
-
-
kW-months/year
$21,156
-
$
TOTAL RECOMMENDED Savings:
$504,801
Cost:
$178,984
$39,115 828,546 $3,556 453 $462,130 - $39,115
828,546
kWh
$3,556
453
kW-months/year
$462,130
-
$
TOTAL IMPLEMENTED Savings:
$494,931
Cost:
$147,984
$39,115 828,546 $3,556 453 $452,260 - $39,115
828,546
kWh
$3,556
453
kW-months/year
$452,260
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes