Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1997 |
Principal Product | Magnetic Sensing Equipment |
NAICS | n/a |
SIC | 3829 - Measuring & Controlling Devices, Nec |
Sales | $5,000,000-$10,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 66,000 |
Annual Production | 30,500 Pieces |
Production Hrs. Annual | 4,420 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $141,496 | 3,066,823 | kWh | $0.05 |
Electricity Demand | $51,905 | 6,466 | kW-months/year | $8.03 |
TOTAL ENERGY COSTS | $193,401 | |||
RECOMMENDED SAVINGS* | $49,139 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $20,466 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $5,486 Cost: $20,719 |
$4,014 | 87,339 | $1,472 | 184 | - | - |
$4,014 87,339 kWh |
$1,472 184 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,264 Cost: $1,984 |
$2,264 | 49,238 | - | - | - | - |
$2,264 49,238 kWh |
- - kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $313 Cost: $133 |
$221 | 4,689 | $92 | 12 | - | - |
$221 4,689 kWh |
$92 12 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $15,189 Cost: $35,749 |
$11,782 | 256,155 | $3,407 | 425 | - | - |
$11,782 256,155 kWh |
$3,407 425 kW-months/year |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $15,704 Cost: $9,000 |
- | - | - | - | $15,704 | - |
- - kWh |
- - kW-months/year |
$15,704 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.8121 COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES |
Savings: $2,700 Cost: $5,800 |
- | - | - | - | $2,700 | - |
- - kWh |
- - kW-months/year |
$2,700 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $5,376 Cost: $35,000 |
- | - | - | - | $5,376 | - |
- - kWh |
- - kW-months/year |
$5,376 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $2,107 Cost: - |
- | - | - | - | $2,107 | - |
- - kWh |
- - kW-months/year |
$2,107 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $49,139 Cost: $108,385 |
$18,281 | 397,421 | $4,971 | 621 | $25,887 | - | $18,281 397,421 kWh |
$4,971 621 kW-months/year |
$25,887 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $20,466 Cost: $43,666 |
$14,267 | 310,082 | $3,499 | 437 | $2,700 | - | $14,267 310,082 kWh |
$3,499 437 kW-months/year |
$2,700 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Electricity Usage | Electricity Demand | Administrative Changes |