Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 1997
Principal Product Magnetic Sensing Equipment
NAICS n/a
SIC 3829 - Measuring & Controlling Devices, Nec
Sales $5,000,000-$10,000,000
# of Employees 180
Plant Area (Sq.Ft.) 66,000
Annual Production 30,500 Pieces
Production Hrs. Annual 4,420
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $141,496 3,066,823 kWh $0.05
Electricity Demand $51,905 6,466 kW-months/year $8.03
TOTAL ENERGY COSTS $193,401
RECOMMENDED SAVINGS* $49,139 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $20,466
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes
$ kWh $ kW-months/year $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,486
Cost:
$20,719
$4,014 87,339 $1,472 184 - - $4,014
87,339
kWh
$1,472
184
kW-months/year
-
-
$
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$2,264
Cost:
$1,984
$2,264 49,238 - - - - $2,264
49,238
kWh
-
-
kW-months/year
-
-
$
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL Savings:
$313
Cost:
$133
$221 4,689 $92 12 - - $221
4,689
kWh
$92
12
kW-months/year
-
-
$
04: 2.2515 USE OPTIMUM THICKNESS INSULATION Savings:
$15,189
Cost:
$35,749
$11,782 256,155 $3,407 425 - - $11,782
256,155
kWh
$3,407
425
kW-months/year
-
-
$
05: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER Savings:
$15,704
Cost:
$9,000
- - - - $15,704 - -
-
kWh
-
-
kW-months/year
$15,704
-
$
06: 3.8121 COVER CONTAINERS TO MINIMIZE EVAPORATIVE LOSSES Savings:
$2,700
Cost:
$5,800
- - - - $2,700 - -
-
kWh
-
-
kW-months/year
$2,700
-
$
07: 4.1110 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK Savings:
$5,376
Cost:
$35,000
- - - - $5,376 - -
-
kWh
-
-
kW-months/year
$5,376
-
$
08: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES Savings:
$2,107
Cost:
-
- - - - $2,107 - -
-
kWh
-
-
kW-months/year
$2,107
-
$
TOTAL RECOMMENDED Savings:
$49,139
Cost:
$108,385
$18,281 397,421 $4,971 621 $25,887 - $18,281
397,421
kWh
$4,971
621
kW-months/year
$25,887
-
$
TOTAL IMPLEMENTED Savings:
$20,466
Cost:
$43,666
$14,267 310,082 $3,499 437 $2,700 - $14,267
310,082
kWh
$3,499
437
kW-months/year
$2,700
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand Administrative Changes Electricity Usage Electricity Demand Administrative Changes