Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 1999 |
Principal Product | Chocolate Candies |
NAICS | n/a |
SIC | 2064 - Candy & Other Confectionery Products |
Sales | n/a |
# of Employees | 77 |
Plant Area (Sq.Ft.) | 0 |
Annual Production | 12,000,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $139,756 | 3,599,062 | kWh | $0.04 |
Electricity Demand | $75,336 | 9,527 | kW-months/year | $7.91 |
LPG | $3,063 | 384 | MMBtu | $7.98 |
TOTAL ENERGY COSTS | $218,155 | |||
RECOMMENDED SAVINGS* | $18,380 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $15,901 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | LPG | Administrative Changes | By-product Production | Electricity Usage | Electricity Demand | LPG | Administrative Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,479 Cost: $7,893 |
$1,511 | 35,170 | $968 | 11 | - | - | - | - | - | - |
$1,511 35,170 kWh |
$968 11 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2515 USE OPTIMUM THICKNESS INSULATION |
Savings: $1,894 Cost: $1,361 |
$1,894 | 43,962 | - | - | - | - | - | - | - | - |
$1,894 43,962 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,287 Cost: - |
$1,103 | 8,792 | $184 | 2 | - | - | - | - | - | - |
$1,103 8,792 kWh |
$184 2 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2223 ENHANCE SENSITIVITY OF TEMPERATURE CONTROL AND CUTOFF |
Savings: $584 Cost: $20 |
- | - | - | - | $584 | 73 | - | - | - | - |
- - kWh |
- - kW-months/year |
$584 73 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $3,670 Cost: - |
$3,670 | 58,324 | - | - | - | - | - | - | - | - |
$3,670 58,324 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $6,767 Cost: $1,605 |
- | - | $(-223) | (-5) | - | - | - | - | $6,990 | - |
- - kWh |
$(-223) (-5) kW-months/year |
- - MMBtu |
- - $ |
$6,990 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $1,699 Cost: $2,720 |
$917 | 7,913 | $442 | 1 | - | - | $340 | - | - | - |
$917 7,913 kWh |
$442 1 kW-months/year |
- - MMBtu |
$340 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $18,380 Cost: $13,599 |
$9,095 | 154,161 | $1,371 | 9 | $584 | 73 | $340 | - | $6,990 | - | $9,095 154,161 kWh |
$1,371 9 kW-months/year |
$584 73 MMBtu |
$340 - $ |
$6,990 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $15,901 Cost: $5,706 |
$7,584 | 118,991 | $403 | (-2) | $584 | 73 | $340 | - | $6,990 | - | $7,584 118,991 kWh |
$403 (-2) kW-months/year |
$584 73 MMBtu |
$340 - $ |
$6,990 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | LPG | Administrative Changes | By-product Production | Electricity Usage | Electricity Demand | LPG | Administrative Changes | By-product Production |