Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2001 |
Principal Product | Newspaper Printing and Publishing |
NAICS | n/a |
SIC | 2711 - Newspapers |
Sales | $10,000,000-$50,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 800,000 |
Annual Production | 28,000,000 Pieces |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $116,852 | 5,480,400 | kWh | $0.02 |
Electricity Demand | $117,010 | 12,354 | kW-months/year | $9.47 |
Fuel Oil #2 | $1,517 | - | MMBtu | - |
TOTAL ENERGY COSTS | $235,379 | |||
RECOMMENDED SAVINGS* | $308,984 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $30,433 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Administrative Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $33,061 Cost: $50,725 |
$33,061 | 674,722 | - | - | - | - | - | - |
$33,061 674,722 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,622 Cost: $1,402 |
$1,497 | 71,280 | $1,125 | 10 | - | - | - | - |
$1,497 71,280 kWh |
$1,125 10 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $5,786 Cost: $2,400 |
$5,786 | 118,076 | - | - | - | - | - | - |
$5,786 118,076 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $3,709 Cost: $2,520 |
$2,209 | 106,872 | $1,500 | 13 | - | - | - | - |
$2,209 106,872 kWh |
$1,500 13 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $2,886 Cost: $410 |
$2,940 | 60,017 | - | - | $(-54) | - | - | - |
$2,940 60,017 kWh |
- - kW-months/year |
$(-54) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES |
Savings: $1,597 Cost: - |
$1,597 | 32,585 | - | - | - | - | - | - |
$1,597 32,585 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $2,098 Cost: - |
$1,383 | 65,901 | - | - | $715 | - | - | - |
$1,383 65,901 kWh |
- - kW-months/year |
$715 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $855 Cost: $553 |
$855 | 40,732 | - | - | - | - | - | - |
$855 40,732 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.2612 USE COOLING TOWER WATER INSTEAD OF REFRIGERATION |
Savings: $19,370 Cost: $90,464 |
$18,650 | 380,616 | - | - | $720 | - | - | - |
$18,650 380,616 kWh |
- - kW-months/year |
$720 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 3.5316 CONTRACT A WOOD PALLET RECYCLING COMPANY |
Savings: $1,800 Cost: - |
- | - | - | - | $1,800 | - | - | - |
- - kWh |
- - kW-months/year |
$1,800 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 4.515 INSTALL SHELVES / RACKS TO UTILIZE UNUSED SPACE |
Savings: $168,000 Cost: $240 |
- | - | - | - | - | - | $168,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$168,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 4.711 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM |
Savings: $67,200 Cost: $9,733 |
- | - | - | - | - | - | $67,200 | - |
- - kWh |
- - kW-months/year |
- - $ |
$67,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $308,984 Cost: $158,447 |
$67,978 | 1,550,801 | $2,625 | 23 | $3,181 | - | $235,200 | - | $67,978 1,550,801 kWh |
$2,625 23 kW-months/year |
$3,181 - $ |
$235,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $30,433 Cost: $94,819 |
$26,788 | 610,704 | $1,125 | 10 | $2,520 | - | - | - | $26,788 610,704 kWh |
$1,125 10 kW-months/year |
$2,520 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Primary Product | Electricity Usage | Electricity Demand | Administrative Changes | Primary Product |