Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2001 |
Principal Product | Mattresses |
NAICS | n/a |
SIC | 2515 - Mattresses And Bedsprings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 152,000 |
Annual Production | 468,000 Pieces |
Production Hrs. Annual | 5,304 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $110,401 | 2,912,960 | kWh | $0.04 |
Electricity Demand | $37,169 | 7,013 | kW-months/year | $5.30 |
Natural Gas | $32,558 | 2,789 | MMBtu | $11.67 |
TOTAL ENERGY COSTS | $180,128 | |||
RECOMMENDED SAVINGS* | $191,357 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $58,542 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Administrative Changes | Increase in Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | % | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8121 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES |
Savings: $11,113 Cost: $50 |
- | - | - | - | $11,113 | - | - | - |
- - kWh |
- - kW-months/year |
$11,113 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $20,296 Cost: $28,400 |
$16,259 | 345,932 | $4,037 | 63 | - | - | - | - |
$16,259 345,932 kWh |
$4,037 63 kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $32,895 Cost: $49,350 |
$19,305 | 410,754 | $10,494 | 165 | $3,096 | - | - | - |
$19,305 410,754 kWh |
$10,494 165 kW-months/year |
$3,096 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $942 Cost: $2,000 |
$942 | 20,039 | - | - | - | - | - | - |
$942 20,039 kWh |
- - kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,343 Cost: $340 |
$5,379 | 89,647 | - | - | $(-36) | - | - | - |
$5,379 89,647 kWh |
- - kW-months/year |
$(-36) - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4323 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT |
Savings: $6,986 Cost: $9,000 |
$6,986 | 116,438 | - | - | - | - | - | - |
$6,986 116,438 kWh |
- - kW-months/year |
- - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $682 Cost: $1,895 |
- | - | - | - | $682 | - | - | - |
- - kWh |
- - kW-months/year |
$682 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $78,000 Cost: $98,800 |
- | - | - | - | - | - | $78,000 | - |
- - kWh |
- - kW-months/year |
- - $ |
$78,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.448 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM |
Savings: $35,100 Cost: $4,494 |
- | - | - | - | $35,100 | - | - | - |
- - kWh |
- - kW-months/year |
$35,100 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $191,357 Cost: $194,329 |
$48,871 | 982,810 | $14,531 | 228 | $49,955 | - | $78,000 | - | $48,871 982,810 kWh |
$14,531 228 kW-months/year |
$49,955 - $ |
$78,000 - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $58,542 Cost: $13,884 |
$12,365 | 206,085 | - | - | $46,177 | - | - | - | $12,365 206,085 kWh |
- - kW-months/year |
$46,177 - $ |
- - % |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | % | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Increase in Production | Electricity Usage | Electricity Demand | Administrative Changes | Increase in Production |