Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2001
Principal Product Cookies
NAICS n/a
SIC 2052 - Cookies And Crackers
Sales n/a
# of Employees 200
Plant Area (Sq.Ft.) 68,500
Annual Production 4,000,000 Pieces
Production Hrs. Annual 6,000
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $140,132 3,156,320 kWh $0.04
Electricity Demand $47,669 6,575 kW-months/year $7.25
TOTAL ENERGY COSTS $187,801
RECOMMENDED SAVINGS* $950,818 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $205,913
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Administrative Changes One-time Revenue or Avoided Cost Primary Product Electricity Usage Electricity Demand Administrative Changes One-time Revenue or Avoided Cost Primary Product
$ kWh $ kW-months/year $ $ $ $ $ $
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,662
Cost:
$6,465
$4,540 103,172 $1,122 13 - - - - - - $4,540
103,172
kWh
$1,122
13
kW-months/year
-
-
$
-
-
$
-
-
$
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,358
Cost:
$500
$4,418 61,355 - - $(-60) - - - - - $4,418
61,355
kWh
-
-
kW-months/year
$(-60)
-
$
-
-
$
-
-
$
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$18,443
Cost:
$30,000
$18,443 419,159 - - - - - - - - $18,443
419,159
kWh
-
-
kW-months/year
-
-
$
-
-
$
-
-
$
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$3,155
Cost:
-
$3,155 43,825 - - - - - - - - $3,155
43,825
kWh
-
-
kW-months/year
-
-
$
-
-
$
-
-
$
05: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$800
Cost:
$2,000
$800 11,119 - - - - - - - - $800
11,119
kWh
-
-
kW-months/year
-
-
$
-
-
$
-
-
$
06: 4.5220 MODIFY STORAGE SPACE TO AVOID RENTAL OF A WAREHOUSE Savings:
$720,000
Cost:
$559,440
- - - - - - $720,000 - - - -
-
kWh
-
-
kW-months/year
-
-
$
$720,000
-
$
-
-
$
07: 4.7110 INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM Savings:
$169,000
Cost:
$176,000
- - - - - - - - $169,000 - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
$
$169,000
-
$
08: 4.6510 INSTALL BACK-UP EQUIPMENT Savings:
$29,400
Cost:
$64,000
- - - - - - - - $29,400 - -
-
kWh
-
-
kW-months/year
-
-
$
-
-
$
$29,400
-
$
TOTAL RECOMMENDED Savings:
$950,818
Cost:
$838,405
$31,356 638,630 $1,122 13 $(-60) - $720,000 - $198,400 - $31,356
638,630
kWh
$1,122
13
kW-months/year
$(-60)
-
$
$720,000
-
$
$198,400
-
$
TOTAL IMPLEMENTED Savings:
$205,913
Cost:
$240,500
$7,573 105,180 - - $(-60) - - - $198,400 - $7,573
105,180
kWh
-
-
kW-months/year
$(-60)
-
$
-
-
$
$198,400
-
$
Savings
Cost
$ kWh $ kW-months/year $ $ $ $ $ $
Electricity Usage Electricity Demand Administrative Changes One-time Revenue or Avoided Cost Primary Product Electricity Usage Electricity Demand Administrative Changes One-time Revenue or Avoided Cost Primary Product