Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2002 |
Principal Product | Labels |
NAICS | n/a |
SIC | 2671 - Paper Coated & Laminated, Packaging |
Sales | $10,000,000-$50,000,000 |
# of Employees | 30 |
Plant Area (Sq.Ft.) | 76,000 |
Annual Production | 28,500,000 Pounds |
Production Hrs. Annual | 4,992 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $106,772 | 2,656,097 | kWh | $0.04 |
Electricity Demand | $32,542 | 6,992 | kW-months/year | $4.65 |
Natural Gas | $183,031 | 21,521 | MMBtu | $8.50 |
TOTAL ENERGY COSTS | $322,345 | |||
RECOMMENDED SAVINGS* | $63,748 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $34,846 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | LPG | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | LPG | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,667 Cost: $654 |
$2,667 | 48,315 | - | - | - | - | - | - | - | - | - | - |
$2,667 48,315 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $5,905 Cost: $4,220 |
- | - | - | - | - | - | $5,905 | 340 | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,905 340 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $5,603 Cost: $14,749 |
$4,375 | 108,839 | $1,228 | 22 | - | - | - | - | - | - | - | - |
$4,375 108,839 kWh |
$1,228 22 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $651 Cost: - |
$651 | 11,798 | - | - | - | - | - | - | - | - | - | - |
$651 11,798 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $3,038 Cost: $820 |
- | - | - | - | $3,038 | 175 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$3,038 175 MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $4,538 Cost: $20,450 |
$2,841 | 70,720 | $1,897 | 34 | - | - | - | - | $(-200) | - | - | - |
$2,841 70,720 kWh |
$1,897 34 kW-months/year |
- - MMBtu |
- - MMBtu |
$(-200) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $10,139 Cost: $18,574 |
$10,139 | 183,694 | - | - | - | - | - | - | - | - | - | - |
$10,139 183,694 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $8,307 Cost: $2,282 |
- | - | - | - | $8,307 | 977 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,307 977 MMBtu |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $11,700 Cost: $7,000 |
- | - | - | - | - | - | - | - | $11,700 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$11,700 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 4.112 REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL |
Savings: $8,320 Cost: $32,000 |
- | - | - | - | - | - | - | - | $8,320 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
$8,320 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $2,880 Cost: $13,500 |
- | - | - | - | - | - | - | - | - | - | $2,880 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
$2,880 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $63,748 Cost: $114,249 |
$20,673 | 423,366 | $3,125 | 56 | $11,345 | 1,152 | $5,905 | 340 | $19,820 | - | $2,880 | - | $20,673 423,366 kWh |
$3,125 56 kW-months/year |
$11,345 1,152 MMBtu |
$5,905 340 MMBtu |
$19,820 - $ |
$2,880 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $34,846 Cost: $58,623 |
$7,693 | 168,952 | $1,228 | 22 | - | - | $5,905 | 340 | $20,020 | - | - | - | $7,693 168,952 kWh |
$1,228 22 kW-months/year |
- - MMBtu |
$5,905 340 MMBtu |
$20,020 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | LPG | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | LPG | Administrative Changes | One-time Revenue or Avoided Cost |