Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2002
Principal Product Corrugated Containers
NAICS n/a
SIC 2653 - Corrugated And Solid Fiber Boxes
Sales $10,000,000-$50,000,000
# of Employees 86
Plant Area (Sq.Ft.) 250,000
Annual Production 960,000 Thousand Feet
Production Hrs. Annual 6,600
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $238,542 5,530,200 kWh $0.04
Electricity Demand $93,447 11,464 kW-months/year $8.15
Natural Gas $225,299 39,482 MMBtu $5.71
TOTAL ENERGY COSTS $564,788
RECOMMENDED SAVINGS* $404,030 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $334,077
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Primary Product Electricity Usage Electricity Demand Natural Gas Administrative Changes Primary Product
$ kWh $ kW-months/year $ MMBtu $ $ $ $
01: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$12,096
Cost:
$7,584
$8,996 209,220 $3,100 32 - - - - - - $8,996
209,220
kWh
$3,100
32
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$21,281
Cost:
$33,167
$15,912 370,048 $5,369 55 - - - - - - $15,912
370,048
kWh
$5,369
55
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
03: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED Savings:
$1,902
Cost:
-
$1,902 29,726 - - - - - - - - $1,902
29,726
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
04: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$1,446
Cost:
$2,000
$1,446 22,592 - - - - - - - - $1,446
22,592
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
05: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,119
Cost:
$1,162
$1,119 17,481 - - - - - - - - $1,119
17,481
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
-
-
$
06: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS Savings:
$17,690
Cost:
$450
- - - - $17,690 3,098 - - - - -
-
kWh
-
-
kW-months/year
$17,690
3,098
MMBtu
-
-
$
-
-
$
07: 2.1213 DIRECT WARMEST AIR TO COMBUSTION INTAKE Savings:
$64,232
Cost:
$59,000
- - - - $64,232 11,249 - - - - -
-
kWh
-
-
kW-months/year
$64,232
11,249
MMBtu
-
-
$
-
-
$
08: 3.5311 RECOVER AND REUSE WASTE MATERIAL Savings:
$4,950
Cost:
$362
- - - - - - $4,950 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$4,950
-
$
-
-
$
09: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS Savings:
$236,669
Cost:
$58,500
- - - - - - - - $236,669 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
$236,669
-
$
10: 4.125 Savings:
$2,700
Cost:
$864
- - - - - - - - $2,700 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
$2,700
-
$
11: 4.611 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE Savings:
$39,945
Cost:
$1,800
- - - - - - $39,945 - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$39,945
-
$
-
-
$
TOTAL RECOMMENDED Savings:
$404,030
Cost:
$164,889
$29,375 649,067 $8,469 87 $81,922 14,347 $44,895 - $239,369 - $29,375
649,067
kWh
$8,469
87
kW-months/year
$81,922
14,347
MMBtu
$44,895
-
$
$239,369
-
$
TOTAL IMPLEMENTED Savings:
$334,077
Cost:
$103,863
$26,354 601,860 $8,469 87 $17,690 3,098 $44,895 - $236,669 - $26,354
601,860
kWh
$8,469
87
kW-months/year
$17,690
3,098
MMBtu
$44,895
-
$
$236,669
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $ $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Primary Product Electricity Usage Electricity Demand Natural Gas Administrative Changes Primary Product