Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2002 |
Principal Product | Precision Metal Parts |
NAICS | n/a |
SIC | 3483 - Ammunition, Exc. For Small Arms, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 85 |
Plant Area (Sq.Ft.) | 61,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 3,744 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $111,479 | 1,867,320 | kWh | $0.06 |
Electricity Demand | $66,677 | 7,843 | kW-months/year | $8.50 |
TOTAL ENERGY COSTS | $178,156 | |||
RECOMMENDED SAVINGS* | $368,084 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $27,160 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $8,113 Cost: $340 |
$8,173 | 86,031 | - | - | $(-60) | - | - | - | - | - |
$8,173 86,031 kWh |
- - kW-months/year |
$(-60) - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $1,774 Cost: $3,840 |
$1,774 | 18,669 | - | - | - | - | - | - | - | - |
$1,774 18,669 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $9,173 Cost: $23,719 |
$6,470 | 107,832 | $2,703 | 27 | - | - | - | - | - | - |
$6,470 107,832 kWh |
$2,703 27 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $959 Cost: $256 |
$959 | 15,977 | - | - | - | - | - | - | - | - |
$959 15,977 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,285 Cost: - |
$663 | 11,056 | - | - | $63 | - | $559 | - | - | - |
$663 11,056 kWh |
- - kW-months/year |
$63 - $ |
$559 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.5131 RECYCLE WHITE WATER |
Savings: $334,620 Cost: $75,000 |
- | - | - | - | - | - | - | - | $334,620 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$334,620 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.448 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM |
Savings: $1,560 Cost: $1,176 |
- | - | - | - | $1,560 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$1,560 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.5315 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER |
Savings: $2,500 Cost: - |
- | - | - | - | - | - | - | - | $2,500 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$2,500 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.624 HIRE ADDITIONAL PERSONNEL TO REDUCE CHANGEOUT TIME |
Savings: $8,100 Cost: $2,160 |
- | - | - | - | $8,100 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$8,100 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $368,084 Cost: $106,491 |
$18,039 | 239,565 | $2,703 | 27 | $9,663 | - | $559 | - | $337,120 | - | $18,039 239,565 kWh |
$2,703 27 kW-months/year |
$9,663 - $ |
$559 - $ |
$337,120 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $27,160 Cost: $30,059 |
$16,417 | 212,532 | $2,703 | 27 | $8,040 | - | - | - | - | - | $16,417 212,532 kWh |
$2,703 27 kW-months/year |
$8,040 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Administrative Changes | Ancillary Material Cost | One-time Revenue or Avoided Cost |