Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2002 |
Principal Product | Control Valves |
NAICS | n/a |
SIC | 3491 - Industrial Valves |
Sales | $10,000,000-$50,000,000 |
# of Employees | 225 |
Plant Area (Sq.Ft.) | 150,000 |
Annual Production | 2,750 Pieces |
Production Hrs. Annual | 4,420 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $214,096 | 4,440,478 | kWh | $0.05 |
Electricity Demand | $83,767 | 11,554 | kW-months/year | $7.25 |
Natural Gas | $29,668 | 34,985 | MMBtu | $0.85 |
TOTAL ENERGY COSTS | $328,353 | |||
RECOMMENDED SAVINGS* | $122,062 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,954 Cost: $340 |
$3,966 | 50,200 | - | - | - | - | $(-12) | - | - | - |
$3,966 50,200 kWh |
- - kW-months/year |
- - lb |
$(-12) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $57,004 Cost: $97,500 |
$57,004 | 721,571 | - | - | - | - | - | - | - | - |
$57,004 721,571 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $27,021 Cost: $84,100 |
$13,761 | 229,353 | $14,095 | 140 | - | - | $(-835) | - | - | - |
$13,761 229,353 kWh |
$14,095 140 kW-months/year |
- - lb |
$(-835) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $2,473 Cost: $10,800 |
- | - | - | - | - | - | $2,473 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$2,473 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $16,134 Cost: $32,723 |
$11,788 | 196,469 | $3,524 | 35 | $822 | 761 | - | - | - | - |
$11,788 196,469 kWh |
$3,524 35 kW-months/year |
$822 761 lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,828 Cost: $1,339 |
$1,828 | 30,466 | - | - | - | - | - | - | - | - |
$1,828 30,466 kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $1,038 Cost: - |
$710 | 8,981 | - | - | - | - | $60 | - | $268 | - |
$710 8,981 kWh |
- - kW-months/year |
- - lb |
$60 - $ |
$268 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $10,690 Cost: $19,381 |
$7,740 | 129,005 | $2,950 | 29 | - | - | - | - | - | - |
$7,740 129,005 kWh |
$2,950 29 kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $1,920 Cost: $1,895 |
- | - | - | - | - | - | $1,920 | - | - | - |
- - kWh |
- - kW-months/year |
- - lb |
$1,920 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $122,062 Cost: $248,078 |
$96,797 | 1,366,045 | $20,569 | 204 | $822 | 761 | $3,606 | - | $268 | - | $96,797 1,366,045 kWh |
$20,569 204 kW-months/year |
$822 761 lb |
$3,606 - $ |
$268 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - lb |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Administrative Changes | Primary Raw Material |