Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2003 |
Principal Product | screen printed T shirts |
NAICS | 323113 - Commercial Screen Printing |
SIC | 2396 - Automotive And Apparel Trimmings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 275 |
Plant Area (Sq.Ft.) | 70,000 |
Annual Production | 0 Pieces |
Production Hrs. Annual | 6,240 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $102,356 | 2,240,960 | kWh | $0.05 |
Electricity Demand | $47,311 | 5,493 | kW-months/year | $8.61 |
Natural Gas | $9,710 | 3,269 | MMBtu | $2.97 |
TOTAL ENERGY COSTS | $159,377 | |||
RECOMMENDED SAVINGS* | $74,009 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $51,285 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $7,390 Cost: $2,948 |
$7,390 | 110,473 | - | - | - | - | - | - |
$7,390 110,473 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,530 Cost: $868 |
- | - | - | - | $1,530 | 545 | - | - |
- - kWh |
- - kW-months/year |
$1,530 545 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $17,331 Cost: $45,500 |
$17,331 | 258,669 | - | - | - | - | - | - |
$17,331 258,669 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2628 UTILIZE A LESS EXPENSIVE COOLING METHOD |
Savings: $7,451 Cost: $740 |
$7,451 | 111,208 | - | - | - | - | - | - |
$7,451 111,208 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $3,598 Cost: $376 |
$1,446 | 31,451 | $2,152 | 20 | - | - | - | - |
$1,446 31,451 kWh |
$2,152 20 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,755 Cost: $852 |
$2,115 | 45,985 | $640 | 6 | - | - | - | - |
$2,115 45,985 kWh |
$640 6 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $15,954 Cost: $436 |
$11,656 | 233,626 | $4,298 | 41 | - | - | - | - |
$11,656 233,626 kWh |
$4,298 41 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.132 PURCHASE NEW EQUIPMENT TO REDUCE MATERIAL USE / COST |
Savings: $18,000 Cost: $4,000 |
- | - | - | - | - | - | $18,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$18,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $74,009 Cost: $55,720 |
$47,389 | 791,412 | $7,090 | 67 | $1,530 | 545 | $18,000 | - | $47,389 791,412 kWh |
$7,090 67 kW-months/year |
$1,530 545 MMBtu |
$18,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $51,285 Cost: $49,936 |
$28,987 | 492,295 | $4,298 | 41 | - | - | $18,000 | - | $28,987 492,295 kWh |
$4,298 41 kW-months/year |
- - MMBtu |
$18,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Primary Product | Electricity Usage | Electricity Demand | Natural Gas | Primary Product |