Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2003 |
Principal Product | Rubber Hoses |
NAICS | 326220 - Rubber and Plastics Hoses and Belting Manufacturing |
SIC | 3052 - Rubber & Plastics Hose & Belting |
Sales | $50,000,000-$100,000,000 |
# of Employees | 550 |
Plant Area (Sq.Ft.) | 424,000 |
Annual Production | 0 Units |
Production Hrs. Annual | 4,160 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $139,737 | 415,987 | kWh | $0.34 |
Natural Gas | $14,297 | 280,325 | MMBtu | $0.05 |
TOTAL ENERGY COSTS | $154,034 | |||
RECOMMENDED SAVINGS* | $161,951 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $161,951 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $19,397 Cost: $57,060 |
$14,297 | 280,325 | $5,100 | 773 | - | - | - | - | - | - |
$14,297 280,325 kWh |
$5,100 773 kW-months/year |
- - gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7132 INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS |
Savings: $1,095 Cost: $2,128 |
$1,095 | 16,589 | - | - | - | - | - | - | - | - |
$1,095 16,589 kWh |
- - kW-months/year |
- - gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $13,612 Cost: - |
$10,775 | 211,283 | - | - | - | - | $1,131 | - | $1,706 | - |
$10,775 211,283 kWh |
- - kW-months/year |
- - gal |
$1,131 - $ |
$1,706 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $11,681 Cost: $376 |
$11,700 | 177,276 | - | - | - | - | $(-19) | - | - | - |
$11,700 177,276 kWh |
- - kW-months/year |
- - gal |
$(-19) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.1294 SEGREGATE SPENT SOLVENTS AND REUSE IN SUBSEQUENT WASHINGS |
Savings: $33,833 Cost: $43,600 |
- | - | - | - | $33,833 | 3,978 | - | - | - | - |
- - kWh |
- - kW-months/year |
$33,833 3,978 gal |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $82,333 Cost: $168,000 |
- | - | - | - | - | - | $82,333 | - | - | - |
- - kWh |
- - kW-months/year |
- - gal |
$82,333 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $161,951 Cost: $271,164 |
$37,867 | 685,473 | $5,100 | 773 | $33,833 | 3,978 | $83,445 | - | $1,706 | - | $37,867 685,473 kWh |
$5,100 773 kW-months/year |
$33,833 3,978 gal |
$83,445 - $ |
$1,706 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $161,951 Cost: $271,164 |
$37,867 | 685,473 | $5,100 | 773 | $33,833 | 3,978 | $83,445 | - | $1,706 | - | $37,867 685,473 kWh |
$5,100 773 kW-months/year |
$33,833 3,978 gal |
$83,445 - $ |
$1,706 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | gal | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Liquid (non-haz) | Personnel Changes | Ancillary Material Cost |