Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2004 |
Principal Product | Processed Meat |
NAICS | 311611 - Animal (except Poultry) Slaughtering |
SIC | 2011 - Meat Packing Plants |
Sales | $100,000,000-$500,000,000 |
# of Employees | 700 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 144,000,000 Pounds |
Production Hrs. Annual | 6,240 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,588,672 | 31,439,730 | kWh | $0.05 |
Electricity Demand | $439,998 | 60,047 | kW-months/year | $7.33 |
Natural Gas | $1,333,303 | 195,385 | MMBtu | $6.82 |
TOTAL ENERGY COSTS | $3,361,973 | |||
RECOMMENDED SAVINGS* | $839,377 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $62,430 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $122,549 Cost: $170,000 |
- | - | - | - | $122,549 | 18,022 | - | - | - | - |
- - kWh |
- - kW-months/year |
$122,549 18,022 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3417 USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT |
Savings: $617,545 Cost: $2,420,000 |
$842,186 | 12,480,000 | $166,549 | 1,749 | $(-355,190) | (-52,157) | $(-36,000) | - | - | - |
$842,186 12,480,000 kWh |
$166,549 1,749 kW-months/year |
$(-355,190) (-52,157) MMBtu |
$(-36,000) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 3.4141 REPLACE THE CHLORINATION STAGE WITH AN OXYGEN OR OZONE STAGE |
Savings: $29,744 Cost: $98,000 |
- | - | - | - | - | - | $(-5,256) | - | $35,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$(-5,256) - $ |
$35,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $38,590 Cost: $48,289 |
$32,778 | 595,956 | $5,812 | 61 | - | - | - | - | - | - |
$32,778 595,956 kWh |
$5,812 61 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $10,480 Cost: $40,000 |
- | - | - | - | - | - | $10,480 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$10,480 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $7,682 Cost: $400 |
$7,658 | 109,402 | - | - | - | - | $24 | - | - | - |
$7,658 109,402 kWh |
- - kW-months/year |
- - MMBtu |
$24 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $7,109 Cost: $37,572 |
$7,109 | 101,556 | - | - | - | - | - | - | - | - |
$7,109 101,556 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $5,678 Cost: $7,900 |
$5,678 | 81,120 | - | - | - | - | - | - | - | - |
$5,678 81,120 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $839,377 Cost: $2,822,161 |
$895,409 | 13,368,034 | $172,361 | 1,810 | $(-232,641) | (-34,135) | $(-30,752) | - | $35,000 | - | $895,409 13,368,034 kWh |
$172,361 1,810 kW-months/year |
$(-232,641) (-34,135) MMBtu |
$(-30,752) - $ |
$35,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $62,430 Cost: $96,589 |
$46,114 | 786,478 | $5,812 | 61 | - | - | $10,504 | - | - | - | $46,114 786,478 kWh |
$5,812 61 kW-months/year |
- - MMBtu |
$10,504 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost | Electricity Usage | Electricity Demand | Natural Gas | Administrative Changes | One-time Revenue or Avoided Cost |