Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2004 |
Principal Product | Lumber, Wooden Poles |
NAICS | 321114 - Wood Preservation |
SIC | 2491 - Wood Preserving |
Sales | $50,000,000-$100,000,000 |
# of Employees | 68 |
Plant Area (Sq.Ft.) | 17,500 |
Annual Production | 24,000,000 Thousand Feet |
Production Hrs. Annual | 2,470 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $181,220 | 3,391,890 | kWh | $0.05 |
Electricity Demand | $37,917 | 5,482 | kW-months/year | $6.92 |
Wood | $60,278 | 2,691 | MMBtu | $22.40 |
TOTAL ENERGY COSTS | $555,838 | |||
RECOMMENDED SAVINGS* | $294,864 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $234,107 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Wood | Administrative Changes | Electricity Usage | Electricity Demand | Wood | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $10,952 Cost: $225 |
- | - | - | - | $10,952 | 1,016 | - | - |
- - kWh |
- - kW-months/year |
$10,952 1,016 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2123 INSULATE FEEDWATER TANK |
Savings: $1,477 Cost: $1,828 |
- | - | - | - | $1,477 | 137 | - | - |
- - kWh |
- - kW-months/year |
$1,477 137 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7121 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT |
Savings: $1,420 Cost: - |
$872 | 15,857 | $548 | 6 | - | - | - | - |
$872 15,857 kWh |
$548 6 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $4,592 Cost: $1,706 |
- | - | - | - | $4,592 | 426 | - | - |
- - kWh |
- - kW-months/year |
$4,592 426 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $172,708 Cost: $330,000 |
- | - | - | - | - | - | $172,708 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$172,708 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.651 INSTALL BACK-UP EQUIPMENT |
Savings: $26,182 Cost: $64,000 |
- | - | - | - | - | - | $26,182 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$26,182 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.448 INSTALL AUTOMATIC PART STORAGE / RETREVAL SYSTEM |
Savings: $59,280 Cost: $260,000 |
- | - | - | - | - | - | $59,280 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$59,280 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.652 REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES |
Savings: $13,200 Cost: $12,000 |
- | - | - | - | - | - | $13,200 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$13,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.812 APPLY FOR INVESTMENT INCENTIVES |
Savings: $5,053 Cost: $60 |
- | - | - | - | - | - | $5,053 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$5,053 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $294,864 Cost: $669,819 |
$872 | 15,857 | $548 | 6 | $17,021 | 1,579 | $276,423 | - | $872 15,857 kWh |
$548 6 kW-months/year |
$17,021 1,579 MMBtu |
$276,423 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $234,107 Cost: $407,991 |
$872 | 15,857 | $548 | 6 | $15,544 | 1,442 | $217,143 | - | $872 15,857 kWh |
$548 6 kW-months/year |
$15,544 1,442 MMBtu |
$217,143 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Wood | Administrative Changes | Electricity Usage | Electricity Demand | Wood | Administrative Changes |