Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2006 |
Principal Product | Brake Hose Assemblies |
NAICS | 332912 - Fluid Power Valve and Hose Fitting Manufacturing |
SIC | 3492 - Fluid Power Valves & Hose Fittings |
Sales | $10,000,000-$50,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 135,000 |
Annual Production | 3,000,000 Pieces |
Production Hrs. Annual | 6,885 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $387,315 | 6,480,002 | kWh | $0.06 |
Electricity Demand | $77,976 | 1,083 | kW-months/year | $72.00 |
TOTAL ENERGY COSTS | $465,291 | |||
RECOMMENDED SAVINGS* | $92,177 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $78,316 |
#|Description |
Savings Cost |
Status | Electricity Usage | Administrative Changes | Ancillary Material Cost | Electricity Usage | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $18,471 Cost: $1,124 |
$18,471 | 307,853 | - | - | - | - |
$18,471 307,853 kWh |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,366 Cost: - |
$1,366 | 30,354 | - | - | - | - |
$1,366 30,354 kWh |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $13,109 Cost: $1,327 |
$13,109 | 218,478 | - | - | - | - |
$13,109 218,478 kWh |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $1,178 Cost: $1,272 |
$1,178 | 18,875 | - | - | - | - |
$1,178 18,875 kWh |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE |
Savings: $15,306 Cost: $1,300 |
$15,306 | 340,128 | - | - | - | - |
$15,306 340,128 kWh |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7229 AIR CONDITION ONLY SPACE NECESSARY |
Savings: $13,549 Cost: $36,650 |
$13,549 | 225,821 | - | - | - | - |
$13,549 225,821 kWh |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.5318 RECYCLE FLUORESCENT LAMPS |
Savings: $312 Cost: $3,496 |
- | - | - | - | $312 | - |
- - kWh |
- - $ |
$312 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $2,448 Cost: $954 |
- | - | - | - | $2,448 | - |
- - kWh |
- - $ |
$2,448 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $26,438 Cost: $1,500 |
- | - | $26,438 | - | - | - |
- - kWh |
$26,438 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $92,177 Cost: $47,623 |
$62,979 | 1,141,509 | $26,438 | - | $2,760 | - | $62,979 1,141,509 kWh |
$26,438 - $ |
$2,760 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $78,316 Cost: $7,477 |
$49,430 | 915,688 | $26,438 | - | $2,448 | - | $49,430 915,688 kWh |
$26,438 - $ |
$2,448 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Administrative Changes | Ancillary Material Cost | Electricity Usage | Administrative Changes | Ancillary Material Cost |