Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2006 |
Principal Product | Pens, Mousepads |
NAICS | 339940 - Office Supplies (except Paper) Manufacturing |
SIC | 3951 - Pens And Mechanical Pencils |
Sales | $50,000,000-$100,000,000 |
# of Employees | 280 |
Plant Area (Sq.Ft.) | 146,000 |
Annual Production | 1 Units |
Production Hrs. Annual | 8,400 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $173,569 | 7,743,640 | kWh | $0.02 |
Electricity Demand | $57,271 | 17,057 | kW-months/year | $3.36 |
TOTAL ENERGY COSTS | $253,492 | |||
RECOMMENDED SAVINGS* | $122,332 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $59,231 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | lb | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $7,955 Cost: $7,050 |
$7,955 | 130,410 | - | - | - | - |
$7,955 130,410 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4235 REMOVE OR CLOSE OFF UNNEEDED COMPRESSED AIR LINES |
Savings: $10,965 Cost: $5,044 |
$10,965 | 158,912 | - | - | - | - |
$10,965 158,912 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,337 Cost: $598 |
$3,337 | 48,369 | - | - | - | - |
$3,337 48,369 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7141 LOWER LIGHT FIXTURES IN HIGH CEILING AREAS |
Savings: $10,260 Cost: $2,640 |
$8,989 | 147,360 | $1,271 | 31 | - | - |
$8,989 147,360 kWh |
$1,271 31 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $4,427 Cost: $15,444 |
$4,427 | 72,576 | - | - | - | - |
$4,427 72,576 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE |
Savings: $55,146 Cost: $7,392 |
$55,146 | 799,224 | - | - | - | - |
$55,146 799,224 kWh |
- - kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $26,845 Cost: $12,045 |
$23,596 | 386,814 | $3,249 | 78 | - | - |
$23,596 386,814 kWh |
$3,249 78 kW-months/year |
- - lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.1291 ELIMINATE PRACTICE OF MIXING WASTE STREAMS |
Savings: $3,397 Cost: $507 |
- | - | - | - | $3,397 | 197,126 |
- - kWh |
- - kW-months/year |
$3,397 197,126 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $122,332 Cost: $50,720 |
$114,415 | 1,743,665 | $4,520 | 109 | $3,397 | 197,126 | $114,415 1,743,665 kWh |
$4,520 109 kW-months/year |
$3,397 197,126 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $59,231 Cost: $36,278 |
$51,314 | 814,031 | $4,520 | 109 | $3,397 | 197,126 | $51,314 814,031 kWh |
$4,520 109 kW-months/year |
$3,397 197,126 lb |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | lb | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Solid Waste (non-haz) | Electricity Usage | Electricity Demand | Solid Waste (non-haz) |