Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2006 |
Principal Product | Southern yellow pine lumber |
NAICS | 321113 - Sawmills |
SIC | 2421 - Sawmills And Planing Mills, General |
Sales | $50,000,000-$100,000,000 |
# of Employees | 220 |
Plant Area (Sq.Ft.) | 12,000 |
Annual Production | 132 Units |
Production Hrs. Annual | 4,080 |
Location (State) | AL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $715,372 | 19,166,226 | kWh | $0.04 |
Electricity Demand | $174,696 | 39,572 | kW-months/year | $4.41 |
Natural Gas | $3,608 | 252 | MMBtu | $14.33 |
TOTAL ENERGY COSTS | $893,676 | |||
RECOMMENDED SAVINGS* | $72,419 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $67,766 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Wood | Electricity Usage | Electricity Demand | Natural Gas | Wood | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED |
Savings: $519 Cost: - |
$519 | 13,666 | - | - | - | - | - | - |
$519 13,666 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $1,705 Cost: - |
$1,271 | 33,456 | $434 | 8 | - | - | - | - |
$1,271 33,456 kWh |
$434 8 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,948 Cost: $8,787 |
$2,170 | 56,270 | $778 | 15 | - | - | - | - |
$2,170 56,270 kWh |
$778 15 kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2522 ISOLATE HOT OR COLD EQUIPMENT |
Savings: $8,414 Cost: $1,095 |
- | - | - | - | - | - | $8,414 | 25,230 |
- - kWh |
- - kW-months/year |
- - MMBtu |
$8,414 25,230 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $40,792 Cost: $517 |
$40,792 | 867,914 | - | - | - | - | - | - |
$40,792 867,914 kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2314 REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT |
Savings: $18,041 Cost: $44,500 |
- | - | - | - | $18,041 | 1,259 | - | - |
- - kWh |
- - kW-months/year |
$18,041 1,259 MMBtu |
- - MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $72,419 Cost: $54,899 |
$44,752 | 971,306 | $1,212 | 23 | $18,041 | 1,259 | $8,414 | 25,230 | $44,752 971,306 kWh |
$1,212 23 kW-months/year |
$18,041 1,259 MMBtu |
$8,414 25,230 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $67,766 Cost: $46,112 |
$41,311 | 881,580 | - | - | $18,041 | 1,259 | $8,414 | 25,230 | $41,311 881,580 kWh |
- - kW-months/year |
$18,041 1,259 MMBtu |
$8,414 25,230 MMBtu |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Wood | Electricity Usage | Electricity Demand | Natural Gas | Wood |