Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2006 |
Principal Product | Refurbish Aircraft components |
NAICS | 333318 - Other Commercial and Service Industry Machinery Manufacturing |
SIC | 3599 - Industrial Machinery, Nec |
Sales | <$500,000 |
# of Employees | 125 |
Plant Area (Sq.Ft.) | 225 |
Annual Production | 300 Pieces |
Production Hrs. Annual | 6,570 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $55,255 | 1,448,114 | kWh | $0.04 |
Electricity Demand | $13,085 | 4,579 | kW-months/year | $2.86 |
Natural Gas | $47,432 | 28,635 | MMBtu | $1.66 |
TOTAL ENERGY COSTS | $115,772 | |||
RECOMMENDED SAVINGS* | $70,758 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $4,721 Cost: $2,760 |
$3,532 | 58,678 | $1,189 | 34 | - | - | - | - | - | - |
$3,532 58,678 kWh |
$1,189 34 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $9,902 Cost: $900 |
$9,902 | 142,477 | - | - | - | - | - | - | - | - |
$9,902 142,477 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $1,971 Cost: $1,275 |
$1,971 | 32,854 | - | - | - | - | - | - | - | - |
$1,971 32,854 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $8,024 Cost: $7,567 |
$7,515 | 108,130 | $509 | 14 | - | - | - | - | - | - |
$7,515 108,130 kWh |
$509 14 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7131 ADD AREA LIGHTING SWITCHES |
Savings: $515 Cost: $2,079 |
$515 | 7,415 | - | - | - | - | - | - | - | - |
$515 7,415 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.7292 LOWER CEILING TO REDUCE CONDITIONED SPACE |
Savings: $21,646 Cost: $1,350 |
$21,646 | 359,564 | - | - | - | - | - | - | - | - |
$21,646 359,564 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $1,876 Cost: $571 |
$1,876 | 31,270 | - | - | - | - | - | - | - | - |
$1,876 31,270 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7233 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT |
Savings: $5,305 Cost: $1,000 |
$473 | 7,884 | $32 | 1 | $4,800 | - | - | - | - | - |
$473 7,884 kWh |
$32 1 kW-months/year |
$4,800 - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $393 Cost: - |
$246 | 1,408 | - | - | $56 | - | - | - | $91 | - |
$246 1,408 kWh |
- - kW-months/year |
$56 - $ |
- - $ |
$91 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $1,973 Cost: - |
$1,973 | 28,190 | - | - | - | - | - | - | - | - |
$1,973 28,190 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7447 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS |
Savings: $1,029 Cost: $3,200 |
$1,029 | 14,696 | - | - | - | - | - | - | - | - |
$1,029 14,696 kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.2691 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS |
Savings: $6,821 Cost: - |
$6,150 | 102,492 | $671 | 19 | - | - | - | - | - | - |
$6,150 102,492 kWh |
$671 19 kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 3.5318 RECYCLE FLUORESCENT LAMPS |
Savings: $342 Cost: $3,237 |
- | - | - | - | - | - | - | - | $342 | - |
- - kWh |
- - kW-months/year |
- - $ |
- - $ |
$342 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $6,240 Cost: $8,000 |
- | - | - | - | - | - | $6,240 | - | - | - |
- - kWh |
- - kW-months/year |
- - $ |
$6,240 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $70,758 Cost: $31,939 |
$56,828 | 895,058 | $2,401 | 68 | $4,856 | - | $6,240 | - | $433 | - | $56,828 895,058 kWh |
$2,401 68 kW-months/year |
$4,856 - $ |
$6,240 - $ |
$433 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Ancillary Material Cost |