IAC logo
IAC Assessment: UF0383
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0383
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2006
Principal Product Newspapers
NAICS 323111 - Commercial Printing (except Screen and Books)
SIC 2711 - Newspapers
Sales $1,000,000-$5,000,000
# of Employees 400
Plant Area (Sq.Ft.) 20,000
Annual Production 4,680,000 Pieces
Production Hrs. Annual 7,462
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $223,120 5,361,000 kWh $0.04
Electricity Demand $100,483 11,778 kW-months/year $8.53
TOTAL ENERGY COSTS $323,603
RECOMMENDED SAVINGS* $31,873 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $11,563
#|Description Savings
Cost
Status Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost
$ kWh $ kW-months/year $ $
01: 2.7134 USE PHOTOCELL CONTROLS Savings:
$952
Cost:
$954
$407 9,697 $545 5 - - $407
9,697
kWh
$545
5
kW-months/year
-
-
$
02: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$3,247
Cost:
$456
$3,247 47,745 - - - - $3,247
47,745
kWh
-
-
kW-months/year
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$9,179
Cost:
$126
$9,179 134,979 - - - - $9,179
134,979
kWh
-
-
kW-months/year
-
-
$
04: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$2,149
Cost:
$1,296
$337 8,015 $93 1 $1,719 - $337
8,015
kWh
$93
1
kW-months/year
$1,719
-
$
05: 2.2522 ISOLATE HOT OR COLD EQUIPMENT Savings:
$602
Cost:
$85
$602 8,857 - - - - $602
8,857
kWh
-
-
kW-months/year
-
-
$
06: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM Savings:
$12,891
Cost:
$2,960
$7,096 168,959 $5,795 57 - - $7,096
168,959
kWh
$5,795
57
kW-months/year
-
-
$
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$2,618
Cost:
-
$2,618 38,500 - - - - $2,618
38,500
kWh
-
-
kW-months/year
-
-
$
08: 2.8123 PAY UTILITY BILLS ON TIME Savings:
$235
Cost:
-
- - - - $235 - -
-
kWh
-
-
kW-months/year
$235
-
$
TOTAL RECOMMENDED Savings:
$31,873
Cost:
$5,877
$23,486 416,752 $6,433 63 $1,954 - $23,486
416,752
kWh
$6,433
63
kW-months/year
$1,954
-
$
TOTAL IMPLEMENTED Savings:
$11,563
Cost:
$1,422
$9,516 142,994 $93 1 $1,954 - $9,516
142,994
kWh
$93
1
kW-months/year
$1,954
-
$
Savings
Cost
$ kWh $ kW-months/year $ $
Electricity Usage Electricity Demand One-time Revenue or Avoided Cost Electricity Usage Electricity Demand One-time Revenue or Avoided Cost