Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2019 |
Principal Product | Roofing Insulation and Composite Materials |
NAICS | 324122 - Asphalt Shingle and Coating Materials Manufacturing |
SIC | 2952 - Asphalt Felts And Coatings |
Sales | $50,000,000-$100,000,000 |
# of Employees | 132 |
Plant Area (Sq.Ft.) | 400,000 |
Annual Production | 8,300,000 Units |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $529,340 | 9,298,571 | kWh | $0.06 |
Electricity Demand | $112,366 | 16,722 | kW-months/year | $6.72 |
Electricity Fees | $78,520 | - | $ | - |
Natural Gas | $817,470 | 373,302 | MMBtu | $2.19 |
TOTAL ENERGY COSTS | $1,565,482 | |||
RECOMMENDED SAVINGS* | $108,567 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $25,449 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.8212 REDUCE DELIVERY SCHEDULES |
Savings: $43,506 Cost: - |
- | - | - | - | - | - | $40,000 | - | $3,506 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$40,000 - $ |
$3,506 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $19,621 Cost: $2,800 |
- | - | - | - | $19,621 | 8,959 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$19,621 8,959 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $14,666 Cost: $30,000 |
- | - | - | - | $14,666 | 6,697 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$14,666 6,697 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2135 REPAIR AND ELIMINATE STEAM LEAKS |
Savings: $14,533 Cost: $1,600 |
- | - | - | - | $14,533 | 6,636 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$14,533 6,636 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $7,991 Cost: $4,959 |
$6,879 | 120,888 | $1,112 | 166 | - | - | - | - | - | - | - | - |
$6,879 120,888 kWh |
$1,112 166 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,925 Cost: $1,308 |
- | - | - | - | $2,925 | 1,336 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$2,925 1,336 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $2,600 Cost: $9,464 |
$2,600 | 45,693 | - | - | - | - | - | - | - | - | - | - |
$2,600 45,693 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $1,990 Cost: - |
$1,990 | 34,969 | - | - | - | - | - | - | - | - | - | - |
$1,990 34,969 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $735 Cost: - |
$537 | 9,442 | - | - | - | - | $90 | - | - | - | $108 | - |
$537 9,442 kWh |
- - kW-months/year |
- - MMBtu |
$90 - $ |
- - $ |
$108 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $108,567 Cost: $50,131 |
$12,006 | 210,992 | $1,112 | 166 | $51,745 | 23,628 | $40,090 | - | $3,506 | - | $108 | - | $12,006 210,992 kWh |
$1,112 166 kW-months/year |
$51,745 23,628 MMBtu |
$40,090 - $ |
$3,506 - $ |
$108 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $25,449 Cost: $7,867 |
$6,879 | 120,888 | $1,112 | 166 | $17,458 | 7,972 | - | - | - | - | - | - | $6,879 120,888 kWh |
$1,112 166 kW-months/year |
$17,458 7,972 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost |