Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2019 |
Principal Product | Rigid Plastics |
NAICS | 326199 - All Other Plastics Product Manufacturing |
SIC | 3089 - Plastics Products, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 180 |
Plant Area (Sq.Ft.) | 498,000 |
Annual Production | 178,358,000 Pounds |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $4,364,349 | 68,538,115 | kWh | $0.06 |
Electricity Demand | $984,019 | 120,164 | kW-months/year | $8.19 |
Electricity Fees | $490,809 | - | $ | - |
Natural Gas | $350,000 | 100,000 | MMBtu | $3.50 |
TOTAL ENERGY COSTS | $6,206,792 | |||
RECOMMENDED SAVINGS* | $727,479 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $96,820 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $371,464 Cost: $1,750,000 |
$560,640 | 8,760,000 | $98,268 | 12,000 | $(-182,324) | (-74,723) | - | - | - | - | $(-105,120) | - | - | - |
$560,640 8,760,000 kWh |
$98,268 12,000 kW-months/year |
$(-182,324) (-74,723) MMBtu |
- - Tgal |
- - $ |
$(-105,120) - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $212,420 Cost: $75,000 |
$158,078 | 2,345,375 | $54,342 | 6,636 | - | - | - | - | - | - | - | - | - | - |
$158,078 2,345,375 kWh |
$54,342 6,636 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $62,330 Cost: $139,780 |
$50,214 | 784,601 | $12,116 | 1,480 | - | - | - | - | - | - | - | - | - | - |
$50,214 784,601 kWh |
$12,116 1,480 kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $22,663 Cost: $18,928 |
$22,663 | 354,117 | - | - | - | - | - | - | - | - | - | - | - | - |
$22,663 354,117 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7491 INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS |
Savings: $19,167 Cost: $89,865 |
$19,167 | 299,480 | - | - | - | - | - | - | - | - | - | - | - | - |
$19,167 299,480 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $9,978 Cost: $400 |
$9,978 | 112,109 | - | - | - | - | - | - | - | - | - | - | - | - |
$9,978 112,109 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $6,897 Cost: - |
$6,707 | 104,801 | - | - | - | - | - | - | $81 | - | - | - | $109 | - |
$6,707 104,801 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
$81 - $ |
- - $ |
$109 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.2522 ISOLATE HOT OR COLD EQUIPMENT |
Savings: $4,945 Cost: $5,090 |
$4,945 | 77,263 | - | - | - | - | - | - | - | - | - | - | - | - |
$4,945 77,263 kWh |
- - kW-months/year |
- - MMBtu |
- - Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 3.4113 TREAT AND REUSE RINSE WATERS |
Savings: $17,615 Cost: - |
- | - | - | - | - | - | $17,615 | 3,724 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$17,615 3,724 Tgal |
- - $ |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $727,479 Cost: $2,079,063 |
$832,392 | 12,837,746 | $164,726 | 20,116 | $(-182,324) | (-74,723) | $17,615 | 3,724 | $81 | - | $(-105,120) | - | $109 | - | $832,392 12,837,746 kWh |
$164,726 20,116 kW-months/year |
$(-182,324) (-74,723) MMBtu |
$17,615 3,724 Tgal |
$81 - $ |
$(-105,120) - $ |
$109 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $96,820 Cost: $140,180 |
$66,899 | 1,001,511 | $12,116 | 1,480 | - | - | $17,615 | 3,724 | $81 | - | - | - | $109 | - | $66,899 1,001,511 kWh |
$12,116 1,480 kW-months/year |
- - MMBtu |
$17,615 3,724 Tgal |
$81 - $ |
- - $ |
$109 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | Tgal | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Water Disposal | Personnel Changes | Administrative Changes | Primary Raw Material |