Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2019 |
Principal Product | Bread Products |
NAICS | 311812 - Commercial Bakeries |
SIC | 2051 - Bread, Cake, And Related Products |
Sales | $10,000,000-$50,000,000 |
# of Employees | 400 |
Plant Area (Sq.Ft.) | 250,000 |
Annual Production | 80,000,000 Pounds |
Production Hrs. Annual | 4,862 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $793,917 | 12,362,955 | kWh | $0.06 |
Electricity Demand | $196,416 | 23,673 | kW-months/year | $8.30 |
Electricity Fees | $3,628 | - | $ | - |
Natural Gas | $853,109 | 242,225 | MMBtu | $3.52 |
TOTAL ENERGY COSTS | $1,932,873 | |||
RECOMMENDED SAVINGS* | $914,306 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $914,306 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $727,193 Cost: $3,000,000 |
$1,035,200 | 16,000,000 | $199,200 | 24,000 | $(-329,607) | (-93,585) | - | - | $(-177,600) | - | - | - |
$1,035,200 16,000,000 kWh |
$199,200 24,000 kW-months/year |
$(-329,607) (-93,585) MMBtu |
- - $ |
$(-177,600) - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT |
Savings: $95,677 Cost: $50,000 |
- | - | - | - | $95,677 | 27,166 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$95,677 27,166 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.2414 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT |
Savings: $75,075 Cost: $4,000 |
- | - | - | - | $75,075 | 21,316 | - | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$75,075 21,316 MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS |
Savings: $5,403 Cost: - |
$3,210 | 49,611 | - | - | - | - | $936 | - | - | - | $1,257 | - |
$3,210 49,611 kWh |
- - kW-months/year |
- - MMBtu |
$936 - $ |
- - $ |
$1,257 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $5,088 Cost: $496 |
$5,088 | 78,642 | - | - | - | - | - | - | - | - | - | - |
$5,088 78,642 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $3,132 Cost: $9,341 |
$3,132 | 48,407 | - | - | - | - | - | - | - | - | - | - |
$3,132 48,407 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,738 Cost: $13,541 |
$2,329 | 36,004 | $409 | 49 | - | - | - | - | - | - | - | - |
$2,329 36,004 kWh |
$409 49 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $914,306 Cost: $3,077,378 |
$1,048,959 | 16,212,664 | $199,609 | 24,049 | $(-158,855) | (-45,104) | $936 | - | $(-177,600) | - | $1,257 | - | $1,048,959 16,212,664 kWh |
$199,609 24,049 kW-months/year |
$(-158,855) (-45,104) MMBtu |
$936 - $ |
$(-177,600) - $ |
$1,257 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $914,306 Cost: $3,077,378 |
$1,048,959 | 16,212,664 | $199,609 | 24,049 | $(-158,855) | (-45,104) | $936 | - | $(-177,600) | - | $1,257 | - | $1,048,959 16,212,664 kWh |
$199,609 24,049 kW-months/year |
$(-158,855) (-45,104) MMBtu |
$936 - $ |
$(-177,600) - $ |
$1,257 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Natural Gas | Personnel Changes | Administrative Changes | Ancillary Material Cost |