Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2019
Principal Product Rutile, Leucoxene, Ilmenite, Staurolite, Zircon and Kyanite
NAICS 325998 - All Other Miscellaneous Chemical Product and Preparation Manufacturing
SIC 2899 - Chemical Preparations, Nec
Sales $10,000,000-$50,000,000
# of Employees 100
Plant Area (Sq.Ft.) 100,000
Annual Production 95,977 Tons
Production Hrs. Annual 6,240
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $93,874 2,528,400 kWh $0.04
Electricity Demand $57,840 13,043 kW-months/year $4.43
Electricity Fees $8,226 - $ -
Natural Gas $797,516 233,264 MMBtu $3.42
TOTAL ENERGY COSTS $957,456
RECOMMENDED SAVINGS* $96,439 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $93,942
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Primary Product Electricity Usage Electricity Demand Natural Gas Primary Product
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$40,174
Cost:
$25,000
- - - - $40,174 11,754 - - -
-
kWh
-
-
kW-months/year
$40,174
11,754
MMBtu
-
-
$
02: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$23,919
Cost:
$1,400
- - - - $23,919 6,998 - - -
-
kWh
-
-
kW-months/year
$23,919
6,998
MMBtu
-
-
$
03: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$9,352
Cost:
$25,847
$5,847 158,040 $3,505 790 - - - - $5,847
158,040
kWh
$3,505
790
kW-months/year
-
-
MMBtu
-
-
$
04: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN Savings:
$1,403
Cost:
$5,998
$1,403 37,913 - - - - - - $1,403
37,913
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
05: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$1,301
Cost:
$421
$1,301 35,168 - - - - - - $1,301
35,168
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
06: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,094
Cost:
$230
$1,094 29,569 - - - - - - $1,094
29,569
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
07: 3.7214 REDUCE OR ELIMINATE WASTE Savings:
$19,196
Cost:
$40,500
- - - - - - $19,196 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$19,196
-
$
TOTAL RECOMMENDED Savings:
$96,439
Cost:
$99,396
$9,645 260,690 $3,505 790 $64,093 18,752 $19,196 - $9,645
260,690
kWh
$3,505
790
kW-months/year
$64,093
18,752
MMBtu
$19,196
-
$
TOTAL IMPLEMENTED Savings:
$93,942
Cost:
$93,168
$7,148 193,208 $3,505 790 $64,093 18,752 $19,196 - $7,148
193,208
kWh
$3,505
790
kW-months/year
$64,093
18,752
MMBtu
$19,196
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Primary Product Electricity Usage Electricity Demand Natural Gas Primary Product