Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2019 |
Principal Product | Organic Silicone Intermediates |
NAICS | 325998 - All Other Miscellaneous Chemical Product and Preparation Manufacturing |
SIC | 2869 - Industrial Organic Chemicals, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 130 |
Plant Area (Sq.Ft.) | 871,200 |
Annual Production | 5,300 Tons |
Production Hrs. Annual | 8,736 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $1,167,286 | 13,525,200 | kWh | $0.09 |
Electricity Demand | $213,798 | 21,928 | kW-months/year | $9.75 |
Electricity Fees | $255,342 | - | $ | - |
Natural Gas | $279,549 | 42,192 | MMBtu | $6.63 |
TOTAL ENERGY COSTS | $1,915,975 | |||
RECOMMENDED SAVINGS* | $451,978 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $446,058 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.3415 USE A FOSSIL FUEL ENGINE TO COGENERATE ELECTRICITY OR MOTIVE POWER; AND UTILIZE HEAT |
Savings: $365,719 Cost: $1,800,000 |
$753,360 | 8,760,000 | $117,000 | 12,000 | $(-565,841) | (-85,397) | $61,200 | - |
$753,360 8,760,000 kWh |
$117,000 12,000 kW-months/year |
$(-565,841) (-85,397) MMBtu |
$61,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $40,964 Cost: $16,606 |
$33,359 | 387,896 | $7,605 | 780 | - | - | - | - |
$33,359 387,896 kWh |
$7,605 780 kW-months/year |
- - MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED |
Savings: $22,041 Cost: $3,368 |
- | - | - | - | $22,041 | 3,326 | - | - |
- - kWh |
- - kW-months/year |
$22,041 3,326 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2511 INSULATE BARE EQUIPMENT |
Savings: $11,463 Cost: $2,551 |
- | - | - | - | $11,463 | 1,730 | - | - |
- - kWh |
- - kW-months/year |
$11,463 1,730 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.1222 INSTALL TURBULATORS |
Savings: $5,920 Cost: $7,500 |
- | - | - | - | $5,920 | 894 | - | - |
- - kWh |
- - kW-months/year |
$5,920 894 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO |
Savings: $5,871 Cost: $1,550 |
- | - | - | - | $5,871 | 886 | - | - |
- - kWh |
- - kW-months/year |
$5,871 886 MMBtu |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $451,978 Cost: $1,831,575 |
$786,719 | 9,147,896 | $124,605 | 12,780 | $(-520,546) | (-78,561) | $61,200 | - | $786,719 9,147,896 kWh |
$124,605 12,780 kW-months/year |
$(-520,546) (-78,561) MMBtu |
$61,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $446,058 Cost: $1,824,075 |
$786,719 | 9,147,896 | $124,605 | 12,780 | $(-526,466) | (-79,455) | $61,200 | - | $786,719 9,147,896 kWh |
$124,605 12,780 kW-months/year |
$(-526,466) (-79,455) MMBtu |
$61,200 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material | Electricity Usage | Electricity Demand | Natural Gas | Primary Raw Material |