IAC logo
IAC Assessment: UF0547
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0547
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2020
Principal Product Reclaimed Water and Bio-Solids
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales $10,000,000-$50,000,000
# of Employees 32
Plant Area (Sq.Ft.) 778,550
Annual Production 4,080,800 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $496,619 7,882,844 kWh $0.06
TOTAL ENERGY COSTS $496,619
RECOMMENDED SAVINGS* $256,917 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $256,917
#|Description Savings
Cost
Status Electricity Usage Personnel Changes Primary Raw Material Electricity Usage Personnel Changes Primary Raw Material
$ kWh $ $ $ $
01: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES Savings:
$234,675
Cost:
$218,100
$234,675 3,725,000 - - - - $234,675
3,725,000
kWh
-
-
$
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$18,816
Cost:
$17,893
$18,816 298,668 - - - - $18,816
298,668
kWh
-
-
$
-
-
$
03: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$3,426
Cost:
-
$2,968 47,115 $271 - $187 - $2,968
47,115
kWh
$271
-
$
$187
-
$
TOTAL RECOMMENDED Savings:
$256,917
Cost:
$235,993
$256,459 4,070,783 $271 - $187 - $256,459
4,070,783
kWh
$271
-
$
$187
-
$
TOTAL IMPLEMENTED Savings:
$256,917
Cost:
$235,993
$256,459 4,070,783 $271 - $187 - $256,459
4,070,783
kWh
$271
-
$
$187
-
$
Savings
Cost
$ kWh $ $ $ $
Electricity Usage Personnel Changes Primary Raw Material Electricity Usage Personnel Changes Primary Raw Material