Select a Center

Arizona State University
Boise State University
Case Western Reserve University
Clemson University
Colorado State University
Georgia Institute of Technology
Indiana University-Purdue University
Lehigh University
Louisiana State University
North Carolina State
Oklahoma State University
Oregon State University
San Diego State University
San Francisco State University
Syracuse University
Tennessee Technological University
Texas A&M, College Station
University of Alabama
University of Dayton
University of Delaware
University of Florida
University of Illinois, Chicago
University of Kentucky
University of Massachusetts
University of Miami
University of Missouri-Columbia
University of Nebraska–Lincoln
University of Texas Rio Grande Valley
University of Utah
University of Wisconsin, Milwaukee
West Virginia University
IAC logo
IAC Assessment: UF0548
Sponsored by:
EERE AMO
IAC logo
IAC Assessment: UF0548
Due to University and State restrictions, IAC assessment activities at your local center may be on hold.
Contact your local center for more details on operating status and available services.

Click here for details about Coronavirus (COVID-19) Recovery Support programs
IAC Center University of Florida
Assessment Year 2020
Principal Product Recycled Water and Biosolids
NAICS 221320 - Sewage Treatment Facilities
SIC 4952 - Sewerage Systems
Sales $35,000,000
# of Employees 37
Plant Area (Sq.Ft.) 2,090,880
Annual Production 8,860,510 Thousand Gallons
Production Hrs. Annual 8,760
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $2,265,986 35,968,031 kWh $0.06
Natural Gas $535,384 180,264 MMBtu $2.97
TOTAL ENERGY COSTS $2,801,370
RECOMMENDED SAVINGS* $560,078 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas By-product Production Electricity Usage Natural Gas By-product Production
$ kWh $ MMBtu $ $
01: 2.6231 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED Savings:
$27,216
Cost:
-
$27,216 432,000 - - - - $27,216
432,000
kWh
-
-
MMBtu
-
-
$
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$23,699
Cost:
$74,548
$23,699 376,179 - - - - $23,699
376,179
kWh
-
-
MMBtu
-
-
$
03: 2.1233 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO Savings:
$16,062
Cost:
$2,800
- - $16,062 5,408 - - -
-
kWh
$16,062
5,408
MMBtu
-
-
$
04: 4.122 DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS Savings:
$493,101
Cost:
$1,875,550
$(-6,899) (-109,500) - - $500,000 - $(-6,899)
(-109,500)
kWh
-
-
MMBtu
$500,000
-
$
TOTAL RECOMMENDED Savings:
$560,078
Cost:
$1,952,898
$44,016 698,679 $16,062 5,408 $500,000 - $44,016
698,679
kWh
$16,062
5,408
MMBtu
$500,000
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - -
-
kWh
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ MMBtu $ $
Electricity Usage Natural Gas By-product Production Electricity Usage Natural Gas By-product Production