Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2020 |
Principal Product | Wastewater Treatment |
NAICS | 221320 - Sewage Treatment Facilities |
SIC | 4952 - Sewerage Systems |
Sales | $10,000,000-$50,000,000 |
# of Employees | 17 |
Plant Area (Sq.Ft.) | 1,203,500 |
Annual Production | 1,901,650 Thousand Gallons |
Production Hrs. Annual | 8,760 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $359,618 | 11,065,169 | kWh | $0.03 |
Electricity Demand | $117,488 | 19,746 | kW-months/year | $5.95 |
TOTAL ENERGY COSTS | $477,106 | |||
RECOMMENDED SAVINGS* | $147,377 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $72,645 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Other Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9141 Install Anaerobic Digester |
Savings: $74,732 Cost: $250,000 |
$28,096 | 878,000 | - | - | $46,636 | 8,557 | - | - | - | - |
$28,096 878,000 kWh |
- - kW-months/year |
$46,636 8,557 MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $19,805 Cost: $25,232 |
$13,509 | 422,146 | $6,296 | 1,058 | - | - | - | - | - | - |
$13,509 422,146 kWh |
$6,296 1,058 kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS |
Savings: $6,420 Cost: $17,086 |
$6,420 | 200,616 | - | - | - | - | - | - | - | - |
$6,420 200,616 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 4.662 LEVEL ONE – ADD COMMUNICATION USING IIOT DEVICES TO EXISTING CONTROL SYSTEM TO MODIFY OPERATIONS |
Savings: $9,363 Cost: - |
- | - | - | - | - | - | $9,363 | - | - | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
$9,363 - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.126 INSTALL SENSORS TO DETECT DEFECTS |
Savings: $3,851 Cost: $15,420 |
$3,851 | 120,352 | - | - | - | - | - | - | - | - |
$3,851 120,352 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 3.4156 USE FLOW CONTROL VALVES ON EQUIPMENT TO OPTIMIZE WATER USE |
Savings: $30,206 Cost: $6,500 |
$30,206 | 943,939 | - | - | - | - | - | - | - | - |
$30,206 943,939 kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.7196 USE RE-USABLE FILTERS |
Savings: $3,000 Cost: $1,906 |
- | - | - | - | - | - | - | - | $3,000 | - |
- - kWh |
- - kW-months/year |
- - MMBtu |
- - $ |
$3,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $147,377 Cost: $316,144 |
$82,082 | 2,565,053 | $6,296 | 1,058 | $46,636 | 8,557 | $9,363 | - | $3,000 | - | $82,082 2,565,053 kWh |
$6,296 1,058 kW-months/year |
$46,636 8,557 MMBtu |
$9,363 - $ |
$3,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $72,645 Cost: $66,144 |
$53,986 | 1,687,053 | $6,296 | 1,058 | - | - | $9,363 | - | $3,000 | - | $53,986 1,687,053 kWh |
$6,296 1,058 kW-months/year |
- - MMBtu |
$9,363 - $ |
$3,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Other Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Other Gas | Administrative Changes | Ancillary Material Cost |