Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2020 |
Principal Product | Alternative Fuels |
NAICS | 325180 - Other Basic Inorganic Chemical Manufacturing |
SIC | 2819 - Industrial Inorganic Chemicals, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 50 |
Plant Area (Sq.Ft.) | 103,000 |
Annual Production | 26,149 Tons |
Production Hrs. Annual | 5,824 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $74,800 | 1,608,806 | kWh | $0.05 |
Electricity Demand | $90,522 | 7,670 | kW-months/year | $11.80 |
Electricity Fees | $44,306 | - | $ | - |
TOTAL ENERGY COSTS | $209,628 | |||
RECOMMENDED SAVINGS* | $1,622,587 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $1,622,587 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | Primary Product | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS |
Savings: $20,597 Cost: $19,045 |
$11,740 | 255,218 | $8,857 | 750 | - | - | - | - |
$11,740 255,218 kWh |
$8,857 750 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,420 Cost: $456 |
$1,420 | 30,872 | - | - | - | - | - | - |
$1,420 30,872 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 4.111 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK |
Savings: $42,983 Cost: $7,127 |
$(-961) | (-20,888) | $(-1,057) | (-90) | - | - | $45,000 | - |
$(-961) (-20,888) kWh |
$(-1,057) (-90) kW-months/year |
- - $ |
$45,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 3.3122 USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS |
Savings: $1,517,489 Cost: $143,275 |
$(-172,059) | (-3,740,409) | $(-8,452) | (-716) | $(-102,000) | - | $1,800,000 | - |
$(-172,059) (-3,740,409) kWh |
$(-8,452) (-716) kW-months/year |
$(-102,000) - $ |
$1,800,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 3.5248 SEPARATE AND RECYCLE SCRAP METAL TO FOUNDRY OR FOR SALE |
Savings: $40,098 Cost: $110,800 |
$(-3,627) | (-78,840) | $(-1,275) | (-108) | - | - | $45,000 | - |
$(-3,627) (-78,840) kWh |
$(-1,275) (-108) kW-months/year |
- - $ |
$45,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,622,587 Cost: $280,703 |
$(-163,487) | (-3,554,047) | $(-1,926) | (-163) | $(-102,000) | - | $1,890,000 | - | $(-163,487) (-3,554,047) kWh |
$(-1,926) (-163) kW-months/year |
$(-102,000) - $ |
$1,890,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $1,622,587 Cost: $280,703 |
$(-163,487) | (-3,554,047) | $(-1,926) | (-163) | $(-102,000) | - | $1,890,000 | - | $(-163,487) (-3,554,047) kWh |
$(-1,926) (-163) kW-months/year |
$(-102,000) - $ |
$1,890,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Primary Product | Electricity Usage | Electricity Demand | Personnel Changes | Primary Product |