Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2020 |
Principal Product | Equine Feed |
NAICS | 311119 - Other Animal Food Manufacturing |
SIC | 2048 - Prepared Feeds, Nec |
Sales | $10,000,000-$50,000,000 |
# of Employees | 85 |
Plant Area (Sq.Ft.) | 390,000 |
Annual Production | 26,000 Tons |
Production Hrs. Annual | 2,080 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $93,001 | 1,335,331 | kWh | $0.07 |
Electricity Demand | $49,615 | 6,741 | kW-months/year | $7.36 |
Electricity Fees | $21,896 | - | $ | - |
Natural Gas | $16,764 | 4,698 | MMBtu | $3.57 |
TOTAL ENERGY COSTS | $188,609 | |||
RECOMMENDED SAVINGS* | $199,673 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $19,987 |
#|Description |
Savings Cost |
Status | Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | MMBtu | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $41,999 Cost: $359,360 |
$41,999 | 599,987 | - | - | - | - | - | - |
$41,999 599,987 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN |
Savings: $4,454 Cost: $5,998 |
$4,454 | 63,630 | - | - | - | - | - | - |
$4,454 63,630 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $3,072 Cost: $8,274 |
$3,072 | 43,879 | - | - | - | - | - | - |
$3,072 43,879 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.2136 INSTALL / REPAIR INSULATION ON STEAM LINES |
Savings: $2,897 Cost: $1,544 |
- | - | $2,897 | 812 | - | - | - | - |
- - kWh |
$2,897 812 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.2122 INSTALL / REPAIR INSULATION ON CONDENSATE LINES |
Savings: $1,841 Cost: $378 |
- | - | $1,841 | 516 | - | - | - | - |
- - kWh |
$1,841 516 MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,156 Cost: $306 |
$1,156 | 16,514 | - | - | - | - | - | - |
$1,156 16,514 kWh |
- - MMBtu |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.664 LEVEL THREE - INSTALL OR MODIFY CONTROL SYSTEM WITH COMMUNICATION AND NONLOCAL EXTERNAL INFORMATION (I.E. WEATHER FORECA |
Savings: $134,615 Cost: $11,004 |
- | - | - | - | - | - | $134,615 | - |
- - kWh |
- - MMBtu |
- - $ |
$134,615 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.463 MODIFY FACILITY TO AVOID EXCESS MAINTENANCE COSTS |
Savings: $9,639 Cost: $725 |
- | - | - | - | $9,639 | - | - | - |
- - kWh |
- - MMBtu |
$9,639 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $199,673 Cost: $387,589 |
$50,681 | 724,010 | $4,738 | 1,328 | $9,639 | - | $134,615 | - | $50,681 724,010 kWh |
$4,738 1,328 MMBtu |
$9,639 - $ |
$134,615 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $19,987 Cost: $8,951 |
$5,610 | 80,144 | $4,738 | 1,328 | $9,639 | - | - | - | $5,610 80,144 kWh |
$4,738 1,328 MMBtu |
$9,639 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | MMBtu | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost | Electricity Usage | Natural Gas | Administrative Changes | Ancillary Material Cost |