IAC logo
IAC Assessment: UF0563
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UF0563
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Florida
Assessment Year 2020
Principal Product Metal Plate Connected Wood Trusses
NAICS 321992 - Prefabricated Wood Building Manufacturing
SIC 2452 - Prefabricated Wood Buildings
Sales $10,000,000-$50,000,000
# of Employees 60
Plant Area (Sq.Ft.) 750,000
Annual Production 19,062,763 Units
Production Hrs. Annual 4,940
Location (State) FL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $184,947 1,038,906 kWh $0.18
LPG $28,980 1,270 MMBtu $22.82
TOTAL ENERGY COSTS $244,457
RECOMMENDED SAVINGS* $39,068 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* $14,617
#|Description Savings
Cost
Status Electricity Usage Personnel Changes Primary Product Electricity Usage Personnel Changes Primary Product
$ kWh $ $ $ $
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY Savings:
$24,451
Cost:
$95,589
$24,451 137,367 - - - - $24,451
137,367
kWh
-
-
$
-
-
$
02: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$5,895
Cost:
$3,125
$5,895 33,120 - - - - $5,895
33,120
kWh
-
-
$
-
-
$
03: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$3,163
Cost:
-
$3,163 17,772 - - - - $3,163
17,772
kWh
-
-
$
-
-
$
04: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$3,026
Cost:
$406
$3,026 17,000 - - - - $3,026
17,000
kWh
-
-
$
-
-
$
05: 2.4222 INSTALL ADEQUATE DRYERS ON AIR LINES TO ELIMINATE BLOWDOWN Savings:
$1,582
Cost:
$735
$1,582 8,886 - - - - $1,582
8,886
kWh
-
-
$
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$951
Cost:
-
$507 2,851 $263 - $181 - $507
2,851
kWh
$263
-
$
$181
-
$
TOTAL RECOMMENDED Savings:
$39,068
Cost:
$99,855
$38,624 216,996 $263 - $181 - $38,624
216,996
kWh
$263
-
$
$181
-
$
TOTAL IMPLEMENTED Savings:
$14,617
Cost:
$4,266
$14,173 79,629 $263 - $181 - $14,173
79,629
kWh
$263
-
$
$181
-
$
Savings
Cost
$ kWh $ $ $ $
Electricity Usage Personnel Changes Primary Product Electricity Usage Personnel Changes Primary Product