Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2022 |
Principal Product | Fire Trucks |
NAICS | 336120 - Heavy Duty Truck Manufacturing |
SIC | 3711 - Motor Vehicles And Car Bodies |
Sales | $10,000,000-$50,000,000 |
# of Employees | 480 |
Plant Area (Sq.Ft.) | 285,596 |
Annual Production | 423 Units |
Production Hrs. Annual | 4,160 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $227,555 | 4,992,261 | kWh | $0.05 |
Electricity Demand | $169,631 | 14,502 | kW-months/year | $11.70 |
Electricity Fees | $10,376 | - | $ | - |
Natural Gas | $27,805 | 7,462 | MMBtu | $3.73 |
LPG | $15,932 | 823 | MMBtu | $19.37 |
Fuel Oil #1 | $130,362 | 6,384 | MMBtu | $20.42 |
TOTAL ENERGY COSTS | $581,661 | |||
RECOMMENDED SAVINGS* | $118,419 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $118,419 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Personnel Changes | By-product Production | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $56,857 Cost: $359,360 |
$28,827 | 626,668 | $28,030 | 2,400 | - | - | - | - |
$28,827 626,668 kWh |
$28,030 2,400 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $27,950 Cost: $26,859 |
$16,075 | 349,458 | $11,875 | 1,015 | - | - | - | - |
$16,075 349,458 kWh |
$11,875 1,015 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4112 INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS |
Savings: $4,159 Cost: $10,627 |
$4,159 | 90,415 | - | - | - | - | - | - |
$4,159 90,415 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME |
Savings: $4,152 Cost: $3,218 |
$4,152 | 90,265 | - | - | - | - | - | - |
$4,152 90,265 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $4,007 Cost: $8,760 |
$4,007 | 87,113 | - | - | - | - | - | - |
$4,007 87,113 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $3,414 Cost: $756 |
$3,414 | 74,210 | - | - | - | - | - | - |
$3,414 74,210 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 3.6193 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS |
Savings: $12,245 Cost: $11,975 |
- | - | - | - | - | - | $12,245 | - |
- - kWh |
- - kW-months/year |
- - $ |
$12,245 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 3.4111 USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION |
Savings: $5,635 Cost: $4,650 |
- | - | - | - | $5,635 | - | - | - |
- - kWh |
- - kW-months/year |
$5,635 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $118,419 Cost: $426,205 |
$60,634 | 1,318,129 | $39,905 | 3,415 | $5,635 | - | $12,245 | - | $60,634 1,318,129 kWh |
$39,905 3,415 kW-months/year |
$5,635 - $ |
$12,245 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $118,419 Cost: $426,205 |
$60,634 | 1,318,129 | $39,905 | 3,415 | $5,635 | - | $12,245 | - | $60,634 1,318,129 kWh |
$39,905 3,415 kW-months/year |
$5,635 - $ |
$12,245 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | By-product Production | Electricity Usage | Electricity Demand | Personnel Changes | By-product Production |