Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2024 |
Principal Product | Healthcare Education Tools |
NAICS | 333249 - Other Industrial Machinery Manufacturing |
SIC | 3559 - Special Industry Machinery, Nec |
Sales | $50,000,000-$100,000,000 |
# of Employees | 364 |
Plant Area (Sq.Ft.) | 96,138 |
Annual Production | 1,800 Units |
Production Hrs. Annual | 2,730 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $67,050 | 981,480 | kWh | $0.07 |
Electricity Demand | $36,538 | 2,915 | kW-months/year | $12.53 |
Electricity Fees | $17,609 | - | $ | - |
TOTAL ENERGY COSTS | $121,197 | |||
RECOMMENDED SAVINGS* | $1,081,701 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $83,700 Cost: $322,608 |
$43,591 | 641,049 | $40,109 | 3,200 | - | - | - | - |
$43,591 641,049 kWh |
$40,109 3,200 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $13,015 Cost: $12,416 |
$4,557 | 67,020 | $(-528) | (-42) | $8,986 | - | - | - |
$4,557 67,020 kWh |
$(-528) (-42) kW-months/year |
$8,986 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $10,599 Cost: $49,000 |
$7,744 | 113,880 | $2,855 | 228 | - | - | - | - |
$7,744 113,880 kWh |
$2,855 228 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $7,230 Cost: $5,280 |
$4,672 | 68,704 | $2,558 | 204 | - | - | - | - |
$4,672 68,704 kWh |
$2,558 204 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.7421 REDUCE GLAZED AREAS IN BUILDINGS |
Savings: $1,046 Cost: $1,720 |
$1,046 | 15,320 | - | - | - | - | - | - |
$1,046 15,320 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.721 INITIATE A PROGRAM TO ACQUIRE ISO CERTIFICATION |
Savings: $890,327 Cost: $117,000 |
$6,674 | 98,148 | $3,653 | 291 | - | - | $880,000 | - |
$6,674 98,148 kWh |
$3,653 291 kW-months/year |
- - $ |
$880,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.446 AUTOMATE FINISHING PROCESS |
Savings: $74,880 Cost: $100,000 |
- | - | - | - | $74,880 | - | - | - |
- - kWh |
- - kW-months/year |
$74,880 - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $904 Cost: $1,752 |
$1,432 | 21,059 | $(-528) | (-42) | - | - | - | - |
$1,432 21,059 kWh |
$(-528) (-42) kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $1,081,701 Cost: $609,776 |
$69,716 | 1,025,180 | $48,119 | 3,839 | $83,866 | - | $880,000 | - | $69,716 1,025,180 kWh |
$48,119 3,839 kW-months/year |
$83,866 - $ |
$880,000 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes | Electricity Usage | Electricity Demand | Personnel Changes | Administrative Changes |