Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Florida |
---|---|
Assessment Year | 2025 |
Principal Product | Custom Metal Parts |
NAICS | 332999 - All Other Miscellaneous Fabricated Metal Product Manufacturing |
SIC | 3499 - Fabricated Metal Products, Nec |
Sales | $1,000,000-$5,000,000 |
# of Employees | 15 |
Plant Area (Sq.Ft.) | 15,000 |
Annual Production | 44,262 Pieces |
Production Hrs. Annual | 2,730 |
Location (State) | FL |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $11,580 | 188,760 | kWh | $0.06 |
Electricity Demand | $12,934 | 994 | kW-months/year | $13.01 |
Electricity Fees | $4,865 | - | $ | - |
Fuel Oil #4 | $51,951 | 64 | MMBtu | $813.64 |
Other Gas | $18,087 | 1,257 | MMBtu | $14.39 |
Other Energy | $16,606 | 1,041 | MMBtu | $15.95 |
TOTAL ENERGY COSTS | $116,023 | |||
RECOMMENDED SAVINGS* | $363,303 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | - |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Natural Gas | Other Energy | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Energy | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7243 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS |
Savings: $45,327 Cost: $12,413 |
$(-557) | (-9,128) | $(-548) | (-42) | - | - | - | - | $46,432 | - |
$(-557) (-9,128) kWh |
$(-548) (-42) kW-months/year |
- - MMBtu |
- - MMBtu |
$46,432 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.9114 USE SOLAR HEAT TO MAKE ELECTRICTY |
Savings: $24,006 Cost: $322,608 |
$11,514 | 188,760 | $12,492 | 960 | - | - | - | - | - | - |
$11,514 188,760 kWh |
$12,492 960 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.4322 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES |
Savings: $15,192 Cost: $55,000 |
$(-1,320) | (-21,638) | $(-94) | (-7) | - | - | $16,606 | 1,041 | - | - |
$(-1,320) (-21,638) kWh |
$(-94) (-7) kW-months/year |
- - MMBtu |
$16,606 1,041 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER |
Savings: $1,712 Cost: $1,016 |
$806 | 13,212 | $906 | 70 | - | - | - | - | - | - |
$806 13,212 kWh |
$906 70 kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 4.114 ADD/MODIFY EQUIPMENT TO IMPROVE DRYING PROCESS |
Savings: $165,176 Cost: $50,246 |
- | - | - | - | $(-14,970) | (-3,000) | - | - | $180,146 | - |
- - kWh |
- - kW-months/year |
$(-14,970) (-3,000) MMBtu |
- - MMBtu |
$180,146 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 4.441 INSTALL AUTOMATIC PACKING EQUIPMENT |
Savings: $89,807 Cost: $7,500 |
$(-56) | (-913) | $(-137) | (-11) | - | - | - | - | $90,000 | - |
$(-56) (-913) kWh |
$(-137) (-11) kW-months/year |
- - MMBtu |
- - MMBtu |
$90,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 4.424 IMPROVE SPACE COMFORT CONDITIONING |
Savings: $22,083 Cost: $2,620 |
$(-585) | (-9,582) | $(-548) | (-42) | - | - | - | - | $23,216 | - |
$(-585) (-9,582) kWh |
$(-548) (-42) kW-months/year |
- - MMBtu |
- - MMBtu |
$23,216 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $363,303 Cost: $451,403 |
$9,802 | 160,711 | $12,071 | 928 | $(-14,970) | (-3,000) | $16,606 | 1,041 | $339,794 | - | $9,802 160,711 kWh |
$12,071 928 kW-months/year |
$(-14,970) (-3,000) MMBtu |
$16,606 1,041 MMBtu |
$339,794 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: - Cost: - |
- | - | - | - | - | - | - | - | - | - | - - kWh |
- - kW-months/year |
- - MMBtu |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | MMBtu | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Natural Gas | Other Energy | Administrative Changes | Electricity Usage | Electricity Demand | Natural Gas | Other Energy | Administrative Changes |