Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | University of Kentucky |
---|---|
Assessment Year | 2013 |
Principal Product | Industrial Resistors |
NAICS | 335314 - Relay and Industrial Control Manufacturing |
SIC | 3625 - Relays And Industrial Controls |
Sales | $10,000,000-$50,000,000 |
# of Employees | 110 |
Plant Area (Sq.Ft.) | 65,000 |
Annual Production | 285,400 Pieces |
Production Hrs. Annual | 4,160 |
Location (State) | KY |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $64,102 | 1,103,517 | kWh | $0.06 |
Electricity Demand | $28,189 | 3,817 | kW-months/year | $7.39 |
Electricity Fees | $14,576 | - | $ | - |
Natural Gas | $11,856 | 1,869 | MMBtu | $6.34 |
TOTAL ENERGY COSTS | $118,723 | |||
RECOMMENDED SAVINGS* | $40,889 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $11,195 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | Electricity Usage | Electricity Demand | Electricity Fees | Natural Gas | Administrative Changes | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $1,240 Cost: $1,930 |
$974 | 16,800 | $266 | 36 | - | - | - | - | - | - |
$974 16,800 kWh |
$266 36 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $943 Cost: $2,750 |
$553 | 9,526 | $390 | 53 | - | - | - | - | - | - |
$553 9,526 kWh |
$390 53 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.6218 TURN OFF EQUIPMENT WHEN NOT IN USE |
Savings: $2,528 Cost: - |
$2,528 | 43,587 | - | - | - | - | - | - | - | - |
$2,528 43,587 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $633 Cost: - |
$633 | 10,926 | - | - | - | - | - | - | - | - |
$633 10,926 kWh |
- - kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $261 Cost: - |
$208 | 3,590 | $53 | 7 | - | - | - | - | - | - |
$208 3,590 kWh |
$53 7 kW-months/year |
- - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS |
Savings: $1,766 Cost: $2,000 |
$446 | 7,680 | $120 | 16 | - | - | $1,200 | 190 | - | - |
$446 7,680 kWh |
$120 16 kW-months/year |
- - $ |
$1,200 190 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.7232 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL |
Savings: $26,356 Cost: $52,000 |
$4,054 | 69,888 | $2,302 | 312 | - | - | - | - | $20,000 | - |
$4,054 69,888 kWh |
$2,302 312 kW-months/year |
- - $ |
- - MMBtu |
$20,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7224 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS |
Savings: $2,395 Cost: $1,200 |
$1,045 | 18,021 | - | - | - | - | $1,350 | 213 | - | - |
$1,045 18,021 kWh |
- - kW-months/year |
- - $ |
$1,350 213 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.3212 OPTIMIZE PLANT POWER FACTOR |
Savings: $4,767 Cost: $1,600 |
- | - | - | - | $4,767 | - | - | - | - | - |
- - kWh |
- - kW-months/year |
$4,767 - $ |
- - MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $40,889 Cost: $61,480 |
$10,441 | 180,018 | $3,131 | 424 | $4,767 | - | $2,550 | 403 | $20,000 | - | $10,441 180,018 kWh |
$3,131 424 kW-months/year |
$4,767 - $ |
$2,550 403 MMBtu |
$20,000 - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $11,195 Cost: $5,530 |
$4,789 | 82,583 | $439 | 60 | $4,767 | - | $1,200 | 190 | - | - | $4,789 82,583 kWh |
$439 60 kW-months/year |
$4,767 - $ |
$1,200 190 MMBtu |
- - $ |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | MMBtu | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||