IAC logo
IAC Assessment: UK2105
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: UK2105
IAC Center University of Kentucky
Assessment Year 2021
Principal Product sunroof motors
NAICS 335312 - Motor and Generator Manufacturing
SIC 3621 - Motors And Generators
Sales $10,000,000-$50,000,000
# of Employees 166
Plant Area (Sq.Ft.) 150,000
Annual Production 157,000,000 Units
Production Hrs. Annual 6,000
Location (State) KY
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $237,234 4,650,000 kWh $0.05
Electricity Demand $177,754 13,502 kW-months/year $13.17
Natural Gas $23,675 2,680 MMBtu $8.83
TOTAL ENERGY COSTS $440,782
RECOMMENDED SAVINGS* $19,157 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes
$ kWh $ kW-months/year $ MMBtu $ $
01: 2.8114 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE Savings:
$701
Cost:
-
- - - - - - $701 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$701
-
$
02: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE Savings:
$1,578
Cost:
-
$1,388 27,220 $190 14 - - - - $1,388
27,220
kWh
$190
14
kW-months/year
-
-
MMBtu
-
-
$
03: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES Savings:
$4,309
Cost:
$2,702
$3,835 75,200 $474 36 - - - - $3,835
75,200
kWh
$474
36
kW-months/year
-
-
MMBtu
-
-
$
04: 2.2511 INSULATE BARE EQUIPMENT Savings:
$1,049
Cost:
$994
$1,569 30,765 - - $(-520) (-59) - - $1,569
30,765
kWh
-
-
kW-months/year
$(-520)
(-59)
MMBtu
-
-
$
05: 2.7228 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM Savings:
$185
Cost:
$332
$185 3,629 - - - - - - $185
3,629
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
06: 2.4111 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS Savings:
$748
Cost:
$540
$443 8,685 $305 23 - - - - $443
8,685
kWh
$305
23
kW-months/year
-
-
MMBtu
-
-
$
07: 2.7135 INSTALL OCCUPANCY SENSORS Savings:
$1,473
Cost:
$3,200
$1,473 28,872 - - - - - - $1,473
28,872
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
08: 2.7124 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED Savings:
$1,440
Cost:
$1,484
$1,440 28,238 - - - - - - $1,440
28,238
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
09: 3.4116 METER RECYCLED WATER (TO REDUCE SEWER CHARGES) Savings:
$1,619
Cost:
$644
- - - - - - $1,619 - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
$1,619
-
$
10: 2.7442 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE Savings:
$1,248
Cost:
$1,000
$75 1,477 - - $1,173 133 - - $75
1,477
kWh
-
-
kW-months/year
$1,173
133
MMBtu
-
-
$
11: 2.7221 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA Savings:
$4,807
Cost:
$400
$4,807 94,248 - - - - - - $4,807
94,248
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
TOTAL RECOMMENDED Savings:
$19,157
Cost:
$11,296
$15,215 298,334 $969 73 $653 74 $2,320 - $15,215
298,334
kWh
$969
73
kW-months/year
$653
74
MMBtu
$2,320
-
$
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - - - - - -
-
kWh
-
-
kW-months/year
-
-
MMBtu
-
-
$
Savings
Cost
$ kWh $ kW-months/year $ MMBtu $ $
Electricity Usage Electricity Demand Natural Gas Administrative Changes Electricity Usage Electricity Demand Natural Gas Administrative Changes