Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Louisville
Assessment Year 1995
Principal Product Plastic Bottle Caps
NAICS n/a
SIC 3089 - Plastics Products, Nec
Sales $50,000,000-$100,000,000
# of Employees 320
Plant Area (Sq.Ft.) 204,000
Annual Production 18,000,000 Pounds
Production Hrs. Annual 8,400
Location (State) IN
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $1,584,362 38,128,957 kWh $0.04
TOTAL ENERGY COSTS $1,584,362
RECOMMENDED SAVINGS* $13,153 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Electricity Usage
$ kWh
01: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS Savings:
$3,704
Cost:
$1,718
$3,704 89,097 $3,704
89,097
kWh
02: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$8,040
Cost:
$100
$8,040 193,435 $8,040
193,435
kWh
03: 2.3212 OPTIMIZE PLANT POWER FACTOR Savings:
$1,409
Cost:
$3,185
$1,409 - $1,409
-
kWh
TOTAL RECOMMENDED Savings:
$13,153
Cost:
$5,003
$13,153 282,532 $13,153
282,532
kWh
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - -
-
kWh
Savings
Cost
$ kWh
Electricity Usage Electricity Usage